WaterMaster
Electromagnetic flowmeter
6 WaterMaster Flow Performance
36
IM/WM–EN Rev. M
6 WaterMaster Flow Performance
6.1 WaterMaster flow performance – m
3
/h
Standard Calibration
0.4 % Class 2
High Accuracy Calibration
0.2 % Class 1
Q4
Q3
Q
0.4%
Q2
Q1
Q
0.2%
Q2
Q1
DN
(m
3
/h)
(m
3
/h)
(m
3
/h)
(m
3
/h)
(m
3
/h)
(m
3
/h)
(m
3
/h)
(m
3
/h)
10
3.1
2.5
0.167
0.013
0.008
0.31
0.02
0.012
15
7.88
6.3
0.42
0.032
0.02
0.79
0.05
0.03
20
12.5
10
0.67
0.05
0.032
1.25
0.08
0.05
25
20
16
1.1
0.08
0.05
2
0.13
0.08
32
31.25
25
1.67
0.13
0.08
3
0.20
0.13
40*
50
40
4.2
0.2
0.13
6
0.32
0.2
50*
79
63
4.2
0.32
0.20
7.9
0.5
0.32
65*
125
100
6.7
0.5
0.32
12.5
0.8
0.5
80*
200
160
10.7
0.81
0.51
16
1.3
0.8
100*
313
250
16.7
1.3
0.79
25
2
1.25
125*
313
250
16.7
1.3
0.79
25
2
1.25
150*
788
630
42
3.2
2.0
63
5
3.2
200*
1,250
1,000
67
5.1
3.2
100
8
5
250
2,000
1,600
107
8.1
5.1
160
13
8
300
3,125
2,500
167
12.7
7.9
250
20
12.5
350
5,000
4,000
267
20.3
12.7
400
32
20
400
5,000
4,000
267
20.3
12.7
400
32
20
450
7,875
6,300
420
32
20
630
50
32
500
7,875
6,300
420
32
20
630
50
32
600
12,500
10,000
667
51
32
1000
80
50
700
20,000
16,000
1600
102
64
1600
160
100
30 in
20,000
16,000
1600
102
64
1600
160
100
800
20,000
16,000
1600
102
64
1600
160
100
900
31,250
25,000
2500
160
100
2500
250
156