VSN800 Weather Station Product Manual
- 11 -
Weather Station Electronics Board, Connect Secondary Sensors (VSN800-14 Model)
The Pyranometer sensors are not interchangeable. The Pyranometer sensor supplied with the
weather stations must be wired to Pyranometer #2.
The PV temperature sensor is not polarity sensitive. Therefore, each signal wire is
interchangeable. The sensor comes with a 25ft length of cable. If the temperature sensor is not
used, it should be terminated with a 0-ohm shunt between the positive and negative signal.
Plane-of-Array Sensor Terminals
Pyranometer #2:
Positive Signal (Red)
Ground:
Negative Signal (Black)
Shield:
Cable Shield and Drain (clear)
PV Temperature Terminal, 1
st
Sensor
PV Temp #1:
Signal (Black or White)
PV Temp #1:
Signal (Black or White)
Shield:
Cable Shield and Drain (bare)
Connect PV panel sensor (VSN800-12 only)
If you are not planning to connect the PV panel temperature sensor, skip this section.
1.
Attach the PV panel temperature sensor so it registers the temperature on the
mounting considerations.
2.
Connect the sensor to the proper location on the circuit board. Note that the PV Temp
#2 connectors are not used for the VSN800-12 Model.
Connect Second Pyranometer
PV Panel
Temperature Sensor
Содержание VSN800