Safety
CI/TTF300-X1
TTF300
EN - 7
1.4.4 Name plate: TTF300 - PROFIBUS PA / FOUNDATION Fieldbus
The name plate is located on the transmitter housing.
A00266
TTF300
PTB 09 ATEX 2016 X
II 1 G Ex ia IIC T6
II 2(1) G Ex [ia]ib IIC T6
II 2G (1D) Ex [iaD]ib IIC T6
T1...T4 Ta. = -40 °C ... +60 °C (Zone 0) ... +85 °C (Zone 1)
T5
Ta. =
T6
Ta. =
TTF300-E1P;
TTF300-E1F; PTB 09 ATEX 2016 X
-40 °C ... +56 °C (Zone 0) ... +71 °C (Zone 1)
-40 °C ... +44 °C (Zone 0) ... +56 °C (Zone 1)
Automation Products GmbH
Alzenau
Germany 2009
TTF300
U = + 9...32 V, I = 12 mA, FISCO
IDENT 3470 [9700], PA-3.01
Ta. = -40°C...+85°C
S
a
O-Code: TTF300-E1P
2400034561
Ser.-No: 2064388
HW. Rev. 1.00
SW. Rev. 1.00.00
IP20
13
14
8
4
7
5
3
2
12
6
1
15
Automation Products GmbH
Alzenau
Germany 2009
TTF300
U = + 9...32 V, I = 12 mA, FISCO
DEVICE_ID 0003200125, ITK - 5.1
Ta. = -40°C...+85°C
S
a
O-Code: TTF300-E1F
2400021437
Ser.-No: 2064567
HW. Rev. 1.00
SW. Rev. 1.00.00
IP20
13
14
8
4
7
5
3
2
12
6
1
15
10 11
9
Fig. 2: Example for ATEX explosion protection
1
Project number
2
Manufacturer of transmitter
3
Country and year of manufacture
4
Order number
5
Serial number
6
Supply voltage range, typical current
range, concept for intrinsically safe
fieldbuses
7
PROFIBUS ID number, protocol /
FOUNDATION Fieldbus device ID
number
8 Ambient temperature range / housing
degree of protection
9
Ex mark (optional)
10
Protection class of hazardous area
design (optional)
11
Temperature class of hazardous area
design (optional)
12
Refer to product documentation
13
Software revision number / hardware
revision number
14
CE mark (EC conformity)
15
Type designation
1.5
Transport safety information
Observe the following information:
• Do not expose the device to moisture during transport. Pack the device accordingly.
• Pack the device so that it is protected from vibration during transport, e.g. through air-
cushioned packaging.