Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
5 Maintenance / 5.3 Cleaning the compressor during operation
© Copyright 2018 . All rights reserved.
HZTL2481_EN
Revision C
May 2018
5.3.1
Wet cleaning with orifice plate on filter silencer (XC2)
Wet cleaning procedure for compressor with XC2
u
Trigger water injection according to the specifications of the en-
ginebuilder.
u
The specified water pressure upstream of the connection to the tur-
bocharger must be maintained.
u
Operate engine for at least five additional minutes after cleaning.
Not more than three cleaning cycles should be conducted consecutively.
Cleaning parameters for XC2 for each turbocharger compressor
Product
Engine load
Water pres-
sure
[bar]
Water
injection time
[sec]
Ø orifice
[mm]
TPL73-A
50 … 85%
2
10
2.5
TPL77-A
2.9
Page
53
/
136