2TLC172125M0201, rev. A 

13 

www.abb.com/lowvoltage 

2011-09-20 

7  EC Declaration of conformity 

 

 

 

ABB AB / JOKAB SAFETY

 Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden 

www.abb.com/lowvoltage 

www.abb.com
www.jokabsafety.com

Original

EC Declaration of conformity

(according to 2006/42/EC, Annex2A)

We

ABB AB
JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden

declare that the safety components of ABB AB make with type designations and safety
functions as listed below, is in conformity with the Directives
2006/42/EC
2006/95/EC
2004/108/EC

Person authorised to compile
the technical file

Lars-Magnus Felth
ABB AB

JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden

Product

Certificate

Serialnumber

Non-contact safety sensor
Eden (Adam , Eva) E/C/EC

44 207 10 372092-001

[000 – 000 ... 999-999]

Adapter unit
Tina 1-8, Tina 10-12

44 207 10 372092-001

[000 – 000 ... 999-999]

Muting unit
FMC-Tina

44 207 10 372092-001

[000 – 000 ... 999-999]

Non-contact safety sensor
including locking function
Magne 2A, 2B, 2AX, 2BX

44 207 10 372092-001

[000 – 000 ... 999-999]

Notified body

TÜV NORD CERT GmbH
Langemarckstrasse 20
45141 Essen
Germany

Notified body No. 0044

Used harmonized standards

EN ISO 12100-1,-2, EN 954-1, EN ISO 13849-1, EN 62061, EN 60204-1,
IEC 60664-1, EN 61000-6-2, EN 61000-6-4, EN 60947-5-1, EN 1088

Mats Linger
MD
Kungsbacka 2011-03-02

Содержание Tina 3A/Aps

Страница 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 3A Aps Adaptor unit ...

Страница 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attenti...

Страница 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 9 Installation precautions 9 Maintenance 9 Testing of the safety functions 9 Troubleshooting 9 5 Operation 10 LED indication 10 Information output signal attributes 10 6 Technical data 11 Dimensions 12 7 EC Declaration of conformity 13 ...

Страница 4: ...r of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipmen...

Страница 5: ...quipped with two additional connection cables for external power supply The Tina3A Aps adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and reduce the risk of electrical interference the unit must be installed within the same physical encapsulation as the safety device The connection cables should be as short as...

Страница 6: ...ot monitored and must therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level fault exclusion refer to EN ISO 13849 2 2003 Annex D The safety loops shall not be used for purposes other than intended All loading or tampering with loops can lead to serious risk of life 5 pole M12 connector 1 Brown 24 VDC 2 White Dynamic signal input 3 Blue ...

Страница 7: ...2TLC172125M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Tina 3A Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 8: ...2TLC172125M0201 rev A 8 www abb com lowvoltage 2011 09 20 Tina 3Aps Caution All cable colours according to ABB Jokab Safety standard cables ...

Страница 9: ...s unit The LED should flash between green and red Interrupt protection The LED should light red The LED should light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of faults Checking and measures to take Lights red Sensor pushed opened Check status of the sensor Bad connection between loops green and or ora...

Страница 10: ...l is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signal No dynamic signal 24 VDC 0 VDC Info output signal pin 5 High High Low High The delay for switching the information signal output fro...

Страница 11: ...tage Dynamic input between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connectors M12 5 pole connector Green loop wires A1 A2 Orange loop wires B1 B2 Brown 24 VDC Blue 0 VDC wires Tina 3Aps only Size ...

Страница 12: ...2TLC172125M0201 rev A 12 www abb com lowvoltage 2011 09 20 Dimensions Tina 3A Tina 3Aps NB All measurements in millimetres ...

Страница 13: ...d to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including lo...

Отзывы: