![ABB SWIFTI CRB 1100 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/abb/swifti-crb-1100/swifti-crb-1100_get-started-manual_5112020.webp)
Configure collaborative safety
—
—
01 PLC
Open PLC configuration
software and set up the
communication among
controller, PLC and laser
scanner
IMPORTANT- The PLC
must be configured in the
192.168.10.XXX segment
and has been uploaded
with the GSD files of the
controller and laser
scanner.
Refer to the OmniCore
operating manual and
PLC configuration manual.
—
02 Laser scanner
Download software Safety
Designer® from SiCK®
official website and open
it.
Set up the
communication among
controller, PLC and laser
scanner, and define
protection fields.
IMPORTANT- The laser
scanner must be
configured in the
192.168.10.XXX segment.
Refer to SICK®
microScan3 instruction
manuals.
PLC software example
19
Step 2 | Software set up
Device tree
Project File Menu
Editing area
PLC