Electrical connection
28
RHDE250 ... 4000 (Contrac) 42/68-167-EN
Pos: 13.4 /Überschriften/1.1/1-spaltig/G - L/Kabelschirm @ 10\mod_1181823716656_3101.doc @ 106187
5.1
Cable shield
Pos: 13.5 /Überschriften/1.1.1/1-spaltig/Signalteil @ 10\mod_1182501083765_3101.doc @ 108573
5.1.1 Signal
part
Pos: 13.6 /Elektrischer Anschluss/Aktorik/Antriebe/Allgemein/Kabelschirm Anschluss @ 10\mod_1181823021906_3101.doc @ 106144
3
3
4
2
2
1
1
M00307
Fig. 14: Fitting the shield
1.
Remove approx. 2 cm of cable sheathing (3) from the end of the cable.
2.
Separate the shield and peel it back to its inner sheathing (4).
3.
Push the cable through the cable gland and fasten with clamp (1).
4.
Make sure that the shielding is touching the clamp and the electronic unit housing (2).
Pos: 13.7 /Überschriften/1.1.1/1-spaltig/Motor @ 10\mod_1182501159359_3101.doc @ 108596
5.1.2 Motor
Pos: 13.8 /Elektrischer Anschluss/Aktorik/Antriebe/Allgemein/Kabelschirm Motor @ 10\mod_1182501238328_3101.doc @ 108619
The cable shield must be connected to the motor in a proper manner.