methods of calculation. If
Ageing rate method is set to "IEC", the relative ageing rate
is calculated as shown in
.
V
IEC
h
=
−
(
)
2
98
6
θ
(Equation 334)
If the setting
Ageing rate method is set to "IEEE", the ageing rate is calculated as
shown in
V
e
IEEE
h
=
+
−
+
15000
110 273
15000
273
θ
(Equation 335)
Where
V
IEC
Momentary ageing rate as per IEC method
V
IEEE
Momentary ageing rate as per IEEE method
θ
h
The calculated hot-spot temperature
If the setting
Insul paper type is set to "Upgraded", the IEEE method is
used for calculating the ageing rate irrespective of the value of
Ageing
rate method setting.
The calculated value of the relative ageing rate,
AGEING_RATE
is given as an output
in the Monitored data view.
The module also calculates the average ageing rate,
AVG_AGE_RATE
, over a specified
time period given by the
Avg Age rate period setting. The setting Avg Age rate
period can be set to "DAY", "WEEK", "MONTH" or "YEAR".
For example, if the
Avg Age rate period is set to "MONTH", the output
AVG_AGE_RATE
is updated every day with the average ageing rate since the day
the calculation started. Once a month is completed, the
AVG_AGE_RATE
is calculated
over the previous 30 days. That is, after the 31st day, the average ageing rate is
calculated from day 2 to day 31 and so on.
If the
Avg Age rate period is set to "DAY", "WEEK" or "MONTH", the calculated
AVG_AGE_RATE
is refreshed every day at 12:00 hours, but if it is set to "YEAR", the
AVG_AGE_RATE
is refreshed once in 30 days.
The calculated
AVG_AGE_RATE
is given as an output in the Monitored data view.
The function considers month as 30 days and correspondingly a year as
12 months or 360 days.
Loss of life calculation
The momentary loss of life can be calculated as the product of the momentary
ageing rate and the time step over which the momentary ageing is calculated.
DL
V
Dt
n
n
=
⋅
(Equation 336)
Condition monitoring functions
1MRS759142 F
1390
REX640
Technical Manual
Содержание RELION REX640
Страница 1: ... RELION PROTECTION AND CONTROL REX640 Technical Manual ...
Страница 2: ......
Страница 3: ...Document ID 1MRS759142 Issued 2023 02 07 Revision F Copyright 2023 ABB All rights reserved ...
Страница 167: ...Figure 62 Signal outputs in power supply module 1MRS759142 F Basic functions REX640 Technical Manual 167 ...
Страница 184: ...Figure 84 mA channels working as mA outputs Basic functions 1MRS759142 F 184 REX640 Technical Manual ...
Страница 1868: ...Figure 989 ANSI extremely inverse time characteristics General function block features 1MRS759142 F 1868 REX640 Technical Manual ...
Страница 1869: ...Figure 990 ANSI very inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1869 ...
Страница 1870: ...Figure 991 ANSI normal inverse time characteristics General function block features 1MRS759142 F 1870 REX640 Technical Manual ...
Страница 1874: ...Figure 995 ANSI long time inverse time characteristics General function block features 1MRS759142 F 1874 REX640 Technical Manual ...
Страница 1875: ...Figure 996 IEC normal inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1875 ...
Страница 1876: ...Figure 997 IEC very inverse time characteristics General function block features 1MRS759142 F 1876 REX640 Technical Manual ...
Страница 1877: ...Figure 998 IEC inverse time characteristics 1MRS759142 F General function block features REX640 Technical Manual 1877 ...
Страница 1878: ...Figure 999 IEC extremely inverse time characteristics General function block features 1MRS759142 F 1878 REX640 Technical Manual ...
Страница 1882: ...Figure 1002 RI type inverse time characteristics General function block features 1MRS759142 F 1882 REX640 Technical Manual ...
Страница 1885: ...Figure 1004 UK rectifier inverse time characteristic 1MRS759142 F General function block features REX640 Technical Manual 1885 ...
Страница 1959: ......