4. Ordering data

Item

Order number

BIO-Tester Relion® REX640 in a waterproof case

•  BIO-Tester Relion®REX640
•  Power supply cable
•  C-60A200 RE_640 tester BIO1001 cable
•  C-61A200 RE_640 tester BIO1002 cable
•  C-62A200 RE_640 tester PSM100x cable
•  C-63A200 RE_640 tester HMI cable

2RCA050442

Power supply cable

2RCA050928

C-60A200 RE_640 tester BIO1001 cable

2RCA050929

C-61A200 RE_640 tester BIO1002 cable

2RCA050930

C-62A200 RE_640 tester PSM100x cable

2RCA050931

C-63A200 RE_640 tester HMI cable

2RCA050932

Table 1: Order codes for BIO-Tester Relion® REX640 and accessories

Содержание RELION REX640

Страница 1: ...BIO Tester Relion REX640 Quick operation guide...

Страница 2: ...onal requirements are complied with In particular any risks in applications where a system failure and or product failure would create a risk for harm to property or persons including but not limited...

Страница 3: ...lways be followed The necessary and required earthing connections must be made according to the product guidelines and regulations When the withdrawable module has been detached from the case do not t...

Страница 4: ...O1002 BIO1004 connector 4 LHMI 48 V DC connector 5 PSM1001 PSM1002 PSM1003 test switches and indication LEDs 6 BIO1001 BIO1003 test switches and indication LEDs 7 BIO1002 BIO1004 test switches and ind...

Страница 5: ...protection relay and the LHMI need to be switched off before the preparations After the auxiliary supply voltage of the protection relay has been switched off it is possible to start the preparations...

Страница 6: ...connector cables between the BIO Tester and the protection relay Connect the separate earth protection lead of BIO Tester to the protective earth pin of the protection relay Connect the connector cab...

Страница 7: ...and the protection relay BIO1001 and BIO1002 have their own connector cables The different power supply modules PSM1001 PSM1002 PSM1003 have the same connector cable Double check that the auxiliary v...

Страница 8: ...protective earth screw T20 on the LHMI but DO NOT remove the existing LHMI s earth lead Connect the separate earth protection lead of BIO Tester Tighten the protective earth screw to 1 5 Nm 10 Follow...

Страница 9: ...Tester to the main s wall plug connector Push the cable connector in place and secure it by turning it clockwise Power up BIO Tester using the mains connection Select the protection relay s operating...

Страница 10: ...IED test mode The test mode can be activated via REX640 LHMI Testing binary inputs Select the correct rated voltage by adjusting the potentiometer Set the input supply voltage level above the set val...

Страница 11: ...640 LHMI Testing and Commissioning page select Force Outputs On the REX640 LHMI module specific page select state On or Off for the selected output channel and tap Force Monitor the status of binary o...

Страница 12: ...ctor cables and put them back inside the BIO Tester case Connect all secondary wiring connector terminals back to the protection relay Ensure the correctness and tightness of connectors Switch on the...

Страница 13: ...lo sure to third parties or utilization of its contents in whole or in parts is forbidden without prior writ ten consent of ABB OY 4 Ordering data Item Order number BIO Tester Relion REX640 in a water...

Страница 14: ...14 BIO TESTER REX640 QUICK OPER ATION GUIDE This page is intentionally left blank...

Страница 15: ...BIO TESTER REX640 QUICK OPER ATION GUIDE 15 This page is intentionally left blank...

Страница 16: ...BB Distribution Solutions Electrification Service P O Box 503 FI 65101 VAASA Finland Phone 358 10 22 11 www abb com service www abb com mediumvoltage Copyright 2019 ABB All rights reserved 2NGA000133...

Отзывы: