The Relay Configuration Tool is based on the IEC 61131-3 standard. The  standard 
defines the programming language used for  configuration. The programmable 
system of REF 54_ feeder terminals allows the output contacts to be operated in 
accordance with the state of the logic inputs and the outputs of the protection, 
control, measurement and condition monitoring functions. The PLC functions (e.g. 
interlocking and alarm logic) are programmed with Boolean functions, timers, 
counters, comparators and flip-flops. The program is written in a function block 
diagram language by using the configuration software.

MOVE

Move

MUL

Extensible multiplier

MUX

Extensible multiplexer

NE

Comparison to greater or less

NOT

Complement

OR

Extensible OR connection

R_TRIG

Rising edge detector

REAL_TO_*

Type conversion from REAL to USINT / UINT / UDINT / SINT / INT / 
DINT

ROL

Rotate to left

ROR

Rotate to right

RS 

Reset dominant bistable function block

RS_D

Reset dominant bistable function block with data input

SEL

Binary selection

SHL

Bit-shift to left

SHR

Bit-shift to right

SIN

Sine in radians

SINT_TO_*

Type conversion from SINT to REAL / INT / DINT

SUB

Subtractor

SQRT

Square root

SR 

Set dominant bistable function block

XOR

Extensible exclusive OR connection

TAN

Tangent in radians

TIME_TO_*

Type conversion from TIME to UDINT / TOD / REAL

TOD_TO_*

Type conversion from TOD to UDINT / TIME / REAL

TOF Off-delay 

timer

TON On-delay 

timer

TP

Pulse

TRUNC_*

Truncation toward zero

UDINT_TO_*

Type conversion from UDINT to USINT / UINT / REAL

UINT_TO_*

Type conversion from UINT to USINT / UDINT / REAL / BOOL

USINT_TO_*

Type conversion from USINT to UINT / UDINT / REAL

WORD_TO_*

Type conversion from WORD to DWORD / BYTE

7DEOH 6WDQGDUGIXQFWLRQVDYDLODEOHIRUWKH5()B

)XQFWLRQ

'HVFULSWLRQ

Содержание REF 54 Series

Страница 1: ...led products from ABB are the building blocks for greater productivity featuring all the tools necessary for lifecycle product support in consistent electronic form 5 B HHGHU 7HUPLQDO 7HFKQLFDO 5HIHUH...

Страница 2: ......

Страница 3: ...toring functions 21 4 1 1 6 Communication functions 21 4 1 1 7 General functions 21 4 1 1 8 Standard functions 22 4 1 2 Configuration 23 4 1 2 1 Feeder terminal configuration 23 4 1 2 2 MIMIC configur...

Страница 4: ...l range 46 4 1 9 3 Transducer supervision 48 4 1 9 4 Signal filtering 48 4 1 9 5 Input scaling linearization 48 4 1 9 6 Transducer connections 49 4 1 9 7 Attributes of an RTD analogue input for feeder...

Страница 5: ...ng 73 4 2 Design description 75 4 2 1 Technical data 75 4 2 2 Terminal diagram of REF 541 80 4 2 3 Terminal diagram of REF 543 81 4 2 4 Terminal diagram of REF 545 82 4 2 5 Terminal diagram of the RTD...

Страница 6: ...VVDU QGH XVWRPHU HHGEDFN SSHQGL 7KH EXV 12 1 Functions supported by the REF 54_ 103 12 2 IEC parameters 103 12 3 The general principle of application data mapping 104 12 4 The principle of the protect...

Страница 7: ...this manual Text added to the table in section Standard functions INDRESET Resetting of operation indicators latched output signals registers and waveforms L H WKH GLVWXUEDQFH UHFRUGHU Section added...

Страница 8: ...of a digital input Selection of input signal range RTD temperature vs resistance Trip circuit supervision Fault indication Fault codes Serial communication LON SPA bus communication on the rear conne...

Страница 9: ...tal signal processing combined with a powerful CPU and distributed I O handling facilitates parallel operations and improves response times and accuracy The HMI including an LCD display with different...

Страница 10: ...1 1 PS1 80 265 Vdc ac Medium 1 1 1 1 1 1 1 1 PS1 18 80 Vdc ac Low 1 1 1 1 PS2 80 265 Vdc PS2 18 80 Vdc LJLWDO 2 ERDUGV BIO1 threshold voltage 140 Vdc 1 1 1 1 1 1 1 1 BIO1 threshold voltage 80 Vdc 1 1...

Страница 11: ...c Medium 1 1 1 1 1 1 1 1 PS1 18 80 Vdc ac Low 1 1 1 1 PS2 80 265 Vdc PS2 18 80 Vdc LJLWDO 2 ERDUGV BIO1 threshold voltage 140 Vdc 1 1 1 1 1 1 1 1 BIO1 threshold voltage 80 Vdc 1 1 1 1 1 1 1 1 BIO1 thr...

Страница 12: ...18 80 Vdc ac Low PS2 80 265 Vdc 1 1 1 1 1 1 1 1 PS2 18 80 Vdc 1 1 LJLWDO 2 ERDUGV BIO1 threshold voltage 140 Vdc 2 2 2 2 BIO1 threshold voltage 80 Vdc 2 2 2 2 BIO1 threshold voltage 18 Vdc 2 2 BIO2 t...

Страница 13: ...ys be followed The device contains components that are sensitive to electrostatic discharge The frame of the device has to be carefully earthed Only a competent electrician is allowed to carry out the...

Страница 14: ...functions can be activated from a wide range of protection control measurement power quality condition monitoring general and communication functions within the scope of I O connections considering th...

Страница 15: ...n with basic functions see Figure 3 1 2 below LJ DVLF IXQFWLRQV RI WKH LQWHJUDWHG IHHGHU WHUPLQDO 5 B In addition REF 54_ offers protection functions for a large variety of applications e g frequency...

Страница 16: ...ervice on page 87 Feeder terminals are measuring instruments and should be handled with care and protected against moisture and mechanical stress especially during transport RQILJXUDWLRQ The REF 54_ f...

Страница 17: ...ther Rogowski coils or conventional current transformers can be used for protection functions based on current measurement Correspondingly voltage dividers or voltage transformers are used for protect...

Страница 18: ...directional overcurrent protection low set stage NOC3High Three phase non directional overcurrent protection high set stage NOC3Inst Three phase non directional overcurrent protection instantaneous st...

Страница 19: ...figuration Tool can be associated with object status indicators that are part of the MIMIC configuration picture displayed on the HMI Object status indicators are used to indicate the status MEAI6 2 G...

Страница 20: ...ector 3 control with indication CODC4 Disconnector 4 control with indication CODC5 Disconnector 5 control with indication COIND1 Switching device 1 indication COIND2 Switching device 2 indication COIN...

Страница 21: ...ented on the CD ROM Technical Descriptions of Functions 1MRS750889 MCD 7DEOH RQGLWLRQLQJ PRQLWRULQJ IXQFWLRQV DYDLODEOH IRU WKH 5 B XQFWLRQ HVFULSWLRQ CMBWEAR1 Circuit breaker electric wear 1 CMBWEAR2...

Страница 22: ...ipal arc sine ATAN Principal arc tangent BITGET Get one bit BITSET Set one bit BOOL_TO_ Type conversion from BOOL to WORD USINT UINT UDINT SINT REAL INT DWORD DINT BYTE BOOL2INT Type conversion from B...

Страница 23: ...ement OR Extensible OR connection R_TRIG Rising edge detector REAL_TO_ Type conversion from REAL to USINT UINT UDINT SINT INT DINT ROL Rotate to left ROR Rotate to right RS Reset dominant bistable fun...

Страница 24: ...oring and the resetting can be done by using the relay command buttons Store and Reset in the Relay Download Tool For more information about the configuration and the Relay Configuration Tool refer to...

Страница 25: ...nfiguration Tool LJ 0 0 FRQILJXUDWLRQ ZLWK WKH 5HOD 0LPLF GLWRU The contents of the alarm view are configured with the Relay Mimic Editor by defining the ON and OFF state texts max 16 characters see F...

Страница 26: ...O cards include a large number of parameters and events In addition general parameters and events are provided e g parameters for control and communication as well as events for testing and self super...

Страница 27: ...ion and settings is the same as the menu structure of the feeder terminal The use of the tool is instructed in the RED Relay Tool Operator s Manual refer to section References on page 96 LJ 0DLQ GLDOR...

Страница 28: ...s a galvanically isolated flyback type DC DC converter A green protection LED indicator on the front panel is lit when the power supply module is in operation The main unit and the external display mo...

Страница 29: ...er supply refer to Table 4 2 1 2 on page 75 RZ DX LOLDU YROWDJH LQGLFDWLRQ The REF 54_ feeder terminal is provided with a low auxiliary voltage indication feature The power supply module issues an int...

Страница 30: ...matching transformers 9 matching transformers CT1 CT2 CT3 CT4 CT5 VT1 VT2 VT3 VT4 In addition to conventional matching transformers current sensors and voltage dividers developed by ABB can be used i...

Страница 31: ...eder terminal configuration and the kind of matching transformers or sensor inputs used Furthermore the feeder terminal includes virtual analogue channels refer to section Calculated analogue channels...

Страница 32: ...b U1c GE1 GE2 GE3 Current Transformer CT1 In 1 A 5 A RS 1 10 VD 1 10 Gen meas 1 3 Not in use IL1 IL2 IL3 IL1b IL2b IL3b I0 I0b U1 U2 U3 U1b U2b U3b U1c GE1 GE2 GE3 Current Transformer CT2 In 1 A 5 A C...

Страница 33: ...mple The scaling factor is not used for general measurement signals connected to the analogue channel The scaling factors for the analogue channels can be set via the HMI of the feeder terminal or wit...

Страница 34: ...of the primary voltage transformer voltage at rated voltage 0 9000 1 1000 correction parameter for the primary transformer phase displacement error at rated voltage 2 00 2 00 9DOXHV WR EH VHW IRU D FX...

Страница 35: ...tion on page 90 Note that this parameter can only be set via the HMI or the Relay Setting Tool 2 Only included in the feeder terminal revisions of the Release 2 0 or later Amplitude error at current I...

Страница 36: ...as 11 and the following as 12 13 etc For example U0s is numbered as 11 and U12s as 12 if these virtual channels are selected for use When sensitive earth fault protection is needed core balance trans...

Страница 37: ...ection References on page 96 7DEOH LJLWDO LQSXWV DYDLODEOH IRU WKH 5 B 5 5 5 Inputs PS1_4_BI1 1 PS1_4_BI1 1 BIO1_5_BI1 PS1_4_BI2 1 PS1_4_BI2 1 BIO1_5_BI2 PS1_4_BI3 1 PS1_4_BI3 1 BIO1_5_BI3 BIO1_5_BI1...

Страница 38: ...t signal is at high state the short low state is filtered and no input status change is detected The low state starting from the time t0 exceeds the filter time which means that the change in the inpu...

Страница 39: ...ut the pulse counter value remains at the present value When an input operates as a pulse counter the positive input transitions 0 1 of a filtered input are counted and the counter value of Input coun...

Страница 40: ...Oscillation hysteresis Note that the oscillation hysteresis must be set lower than the oscillation level to enable the input to be restored from oscillation When the input returns to a non oscillating...

Страница 41: ...ALSE 0 The BI value changes on the rising or falling edge of the input To prevent undesired status changes of the digital input due to e g switch debouncing the change of the attribute value is delaye...

Страница 42: ...ion included 7DEOH LJLWDO RXWSXWV 5 5 5 Outputs PS1_4_HSPO1 1 PS1_4_HSPO1 1 PS2_4_HSPO1 1 PS1_4_HSPO2 1 PS1_4_HSPO2 1 PS2_4_HSPO2 1 PS1_4_HSPO3 PS1_4_HSPO3 PS2_4_HSPO3 PS1_4_HSPO4 PS1_4_HSPO4 PS2_4_HS...

Страница 43: ...utput is recommended to be used for tripping purposes When TCS is used see Table 4 1 8 1 on page 42 the outputs are connected as shown in Figure 4 1 11 1 on page 58 LJ LJK VSHHG GRXEOH SROH SRZHU RXWS...

Страница 44: ...an be used for tripping purposes and for circuit breaker and disconnector control LJ 6LQJOH SROH SRZHU RXWSXWV 2 B B32 DQG 2 B B32 DQG WKH KLJK VSHHG VLQJOH SROH SRZHU RXWSXW 36 B B 632 RXEOH SROH SRZ...

Страница 45: ...pacity see the figure below LJ 6LQJOH SROH SRZHU RXWSXWV 32 6LJQDO RXWSXWV 62 The signalling relay outputs BIO1_5_SO_ are not heavy duty outputs and thus they cannot be used for controlling e g a circ...

Страница 46: ...c Input mode parameters that can be found in the menu Configuration RTD1 Input The default value is Off which means that the channel is not sampled at all and the IN IN and SHUNT terminals are at high...

Страница 47: ...1 0 5 mA 2 1 5 mA 3 0 10 mA 4 0 20 mA 5 4 20 mA 6 1 1 mA 7 2 5 2 5 mA 8 5 5 mA 9 10 10 mA 10 20 20 mA Resistance range 0 0 100 0 100 1 0 200 2 0 500 3 0 1000 4 0 2000 5 0 5000 6 0 10000 Temperature r...

Страница 48: ...h the programmed level due to too high impedance in the circuit the invalid signal is immediately activated The invalid signal is deactivated as soon as the circuit resistance is low enough 6LJQDO ILO...

Страница 49: ...each channel Further one connection screw analogue ground has been reserved per every two channels Two earth terminals see figure below located to the left of the connectors are reserved for connectin...

Страница 50: ...he incoming voltage signal is connected to the IN terminal and the return voltage signal lead to the IN terminal LJ 3ULQFLSOH GLDJUDP IRU WKH FRQQHFWLRQ RI YROWDJH WUDQVGXFHUV The GND terminals are ga...

Страница 51: ...sensor is connected across the IN and IN inputs and the side of the resistor RTD sensor is connected to the GND input The leads connected to the IN and GND inputs must be of the same type LJ 3ULQFLSOH...

Страница 52: ...w limit an open loop condition is detected only possible on resistance and temperature measuring modes or the continuous recalibration of the module has failed The value AI is not locked when the inva...

Страница 53: ...re thorough test of the hardware is performed by the continuous recalibration procedure which will catch errors that degrade the measurement accuracy DOLEUDWLRQ The RTD analogue module is calibrated a...

Страница 54: ...7 5 1230 149 79 10 580 119 40 298 5 1194 129 1 154 92 322 75 1291 123 24 308 1 1232 4 135 3 162 36 338 25 1353 165 90 11 352 127 07 317 675 1270 7 141 7 170 04 354 25 1417 130 89 327 225 1308 9 148 3...

Страница 55: ...by the attributes AO REAL type and AO IV BOOL type where denotes the number of the output These attributes are available in the feeder terminal configuration and can be used for different purposes 9DO...

Страница 56: ...y the MEAO1 MEAO4 analogue output function blocks As an example to display the measured value of neutral current on an analogue gauge the neutral current measurement block MECU1A is connected to MEAO1...

Страница 57: ...ch other The constant current generator forces a 1 5 mA measuring current through the circuit breaker trip circuit The constant current generator is connected over the trip contact of the feeder termi...

Страница 58: ...e defined in the feeder terminal configuration The trip circuit supervision inputs in the feeder terminal configuration are as follows TCS1 and TCS2 inputs in REF 541 and REF 543 TCS1 and TCS2 inputs...

Страница 59: ...rnal fault be detected the contact gap 3 5 is opened LJ 6HOI VXSHUYLVLRQ RXWSXW 5 When a fault has been detected the green Ready indicator starts blinking a fault indication text is displayed on the H...

Страница 60: ...an internal fault appears in REF 54_ the self supervision system generates an IRF code that indicates the type of the fault The fault code can be read from the feeder terminal main menu Status General...

Страница 61: ...RS 485 connection on the rear panel connects the feeder terminal to the distribution automation system via the SPA bus or the LON bus The fibre optic interface module type RER 103 is used to connect t...

Страница 62: ...ease this blocking situation by writing the value 1 to the V202 variable Adjustable LON serial communication parameters are Subnet number Node number and Bit rate The bit rate 78 1 kbps on the LON pro...

Страница 63: ...ia the LON bus 1 6 VWHP VWUXFWXUH The system very often resembles the system in the figure below The protection control or alarm functions are implemented by using REF 54_ feeder terminals SPACOM unit...

Страница 64: ...ector X3 2 DWD W SH 5 0LFUR6 5 DQG 6 GHYLFHV WR HDFK RWKHU Control commands transparent SPA bus messages Events and alarms sliding window protocol Status of breakers and isolators sliding window proto...

Страница 65: ...VHG VXEVWDWLRQ DXWRPDWLRQ V VWHP C E F I 0 C E F I 0 SMSbus1 C E F I 0 C E F I 0 REF 54_ terminals connected via the RER 103 to LON and via the RER 123 to IEC Optical CAP 501 505 SMS 510 RS 485 IEC MA...

Страница 66: ...state for sending and receiving process data The LON inputs and outputs are accessible in the feeder terminal configuration and can be freely used for different types of data transfer between REF 54_...

Страница 67: ...over the LON network to all communication inputs that are bound to the output The network variable connection can be from a single source to one or many sinks An output can also be unbound i e it is n...

Страница 68: ...s of data will occur The system is however designed to always send the latest value when there is communication bandwidth available It may be necessary to use a data latch with timer mechanism in the...

Страница 69: ...d refer to the instructions given for default time outs An over dimensioned longer time out will not cause any harm because the operation will always be faster in real life than the maximum time out O...

Страница 70: ...clear C and enter E optically isolated serial communication port backlight and contrast control freely programmable button F button for remote local control Control position button R L LJ URQW YLHZ R...

Страница 71: ...L 1 A 0 0 2 4 8 0 I L 2 A 0 0 2 5 1 0 I L 3 A 0 0 2 5 0 0 P o w e r P k W 0 0 6 9 2 8 N O C 3 L o w 3 1 E 1 1 9 9 9 1 2 2 4 1 8 3 5 1 2 2 3 0 N O C 3 L o w 3 1 E 1 1 9 9 9 1 2 2 4 1 8 3 5 1 2 3 3 0 N...

Страница 72: ...Successful acknowledgement clears the time stamp line of the alarm view and the corresponding alarm LED An event is generated on the rising and falling edge of the ON signal and by acknowledgement Ala...

Страница 73: ...OLQNLQJ V QWHUORFNLQJ The interlocking LED text can be defined in the same manner as for the other alarm channels The color of the interlocking LED is yellow and cannot be changed The normal LED state...

Страница 74: ...ctivation of the interlocking bypass mode activates the interlocking enable signals of all control objects Thus all local control actions are possible and the enable signals OPENENA CLOSEENA of contro...

Страница 75: ...SRZHU VXSSOLHV Type PS1 240V REF 541 REF 543 PS2 240V REF 545 only External display module PS1 48V REF 541 REF 543 PS2 48V REF 545 only Input voltage ac 110 120 220 240 V Input voltage dc 110 125 220...

Страница 76: ...74 0 1 7DEOH 6LJQDO RXWSXWV Max system voltage 250 V ac dc Continuous carry 5 A Make and carry for 0 5 s 10 A Make and carry for 3 s 8 A Breaking capacity when control circuit time constant L R 40 ms...

Страница 77: ...C immunity test level fulfills the requirements listed below 1 MHz burst disturbance test class III IEC 60255 22 1 common mode 2 5 kV differential mode 1 0 kV Electrostatic discharge test class III IE...

Страница 78: ...nterface connector X3 4 RJ45 connection galvanically isolated RJ45 connection for an external display panel protocol CAN communication cable 1MRS 120511 001 1 m 1MRS 120511 003 3 m Front panel optical...

Страница 79: ...module RTD analogue input module Internal communication bus A D converters and analogue multiplexers Mechanical dimensions Width 223 7 mm 1 2 of a 19 rack Height frame 265 9 mm 6U Height box 249 8 mm...

Страница 80: ...3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 X5 1 5 6 7 9 8 10 12 11 13 15 14 16 18 17 1 2 X5 2 REF 541 1MRS 090115 AABA BABA CABA BIO1_5_BI1 BIO1_5_BI11 BIO1_5_BI9 BIO1_5_BI8 BIO1_5_BI7 BIO1_5_BI6 BIO1_...

Страница 81: ...1_4_BI2 PS1_4_TempAlarm REF 543 1MRS 090127 AABA BABA CABA BIO2_7_BI9 BIO2_7_BI8 BIO2_7_BI7 BIO2_7_BI6 BIO2_7_BI5 BIO2_7_BI4 BIO2_7_BI3 BIO2_7_BI2 BIO2_7_BI10 BIO2_7_BI1 BIO2_7_PO1 BIO2_7_PO2 BIO2_7_P...

Страница 82: ..._BI8 BIO1_5_BI7 BIO1_5_BI6 BIO1_5_BI5 BIO1_5_BI4 BIO1_5_BI3 BIO1_5_BI2 BIO1_5_BI10 BIO1_5_BI12 BIO1_6_BI1 BIO1_6_BI11 BIO1_6_BI9 BIO1_6_BI8 BIO1_6_BI7 BIO1_6_BI6 BIO1_6_BI5 BIO1_6_BI4 BIO1_6_BI3 BIO1_...

Страница 83: ...f shielded twin BNC connector e g type AMP 332225 or Amphenol 31 224 is used to improve reliability and protection against disturbances The current and or voltage sensor used must have a connector tha...

Страница 84: ...utputs are connected to the terminals X6 1 1 and X6 1 2 The feeder terminal self supervision output IRF is linked to the terminals X4 1 3 X4 1 4 and X4 1 5 Protective earth is connected to the screw m...

Страница 85: ...X2 3 1 2 X2 4 1 2 X2 5 1 2 X2 6 1 2 X2 7 1 2 X2 8 1 2 X2 9 1 2 CE REF541D_115AABA BABA CABA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9...

Страница 86: ...17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 X3 4 Made in Finland X2 1 1 2 X2 2 1 2 X2 3 1 2 X2 4 1 2 X2 5 1 2 X2 6 1 2 X2 7 1 2 X2 8 1 2 X2 9 1 2 CE REF543B_129AABB BABB ExtMMI_a CNV BIO2 CPU1...

Страница 87: ...ed All repairs are to be taken by the manufacturer Please contact the manufacturer or its nearest representative for further information about checking overhaul and recalibration of the terminal To ac...

Страница 88: ...ction and power factor control functions are available XQFWLRQDOLW OHYHO 6HOHFWLRQ RI IXQFWLRQ EORFNV C Control All control condition monitoring and measurement functions B Basic All control condition...

Страница 89: ...be supplied with an RTD analogue module For more detailed information about the hardware of REF 54_ refer to section Hardware versions on page 9 6RIWZDUH FRQILJXUDWLRQ Each REF 54_ feeder terminal al...

Страница 90: ...ling factor for channels 1 10 For further information refer to section Scaling the rated values of the protected unit for analogue channels on page 33 Technical data of the VT1 VT2 VT3 and VT4 voltage...

Страница 91: ...Extended 4 mm clearance according to IEC 60664 1 Insulation coordination for equipment within low voltage systems New CPU module with a SW downloading port X3 1 at the rear plate of the relay 5HOD FRQ...

Страница 92: ...Improved storing shorter storing time New language versions English Swedish English Finnish An informative parameter Config capacity added Main menu Configuration General Config capacity For further...

Страница 93: ...t Three phase start up supervision for motors TOL3Dev Three phase thermal overload protection for devices XQFWLRQ HVFULSWLRQ MEAI1 General measurement 1 analogue input on RTD analogue module MEAI2 Gen...

Страница 94: ...ith the digital input voltage range 24 48 60 110 125 220 V dc 7RROV Uploading downloading of the Relay Configuration Tool project RCT in CAP 505 from to the feeder terminal via SPA or LON Uploading do...

Страница 95: ...rear connectors DUGZDUH PHFKDQLFV Voltage threshold for digital inputs power supply PS1 240 V High 110 120 220 240 V ac or 110 125 220 V dc with the digital input nominal voltage 220 V dc 7RROV Protoc...

Страница 96: ...List for REF 541 and REF 543 1 1MRS751774 MTI Parameter List for REF 545 1 1MRS751775 MTI Event List for REF 541 and REF 543 1 1MRS751776 MTI Event List for REF 545 1 1MRS751777 MTI Technical Descrip...

Страница 97: ...NMARKTM LONMARK interoperability association is an independent world wide industry association which facilitates the development and implementation of open interoperable LonWorks based control product...

Страница 98: ...uration 16 23 24 Connections 83 Connectors 83 Control functions 19 CPU load 14 89 CPU module 9 10 11 12 91 94 97 102 Current measurement 17 Current sensor 10 11 12 30 34 Current transformer 10 11 12 1...

Страница 99: ...ork configuration 16 26 LON Network Tool 26 0 Manuals 96 Matching transformer 30 Measurement functions 15 18 Measuring devices 33 Mechanical dimensions 79 MIMIC picture 25 MMI 10 11 12 14 27 69 1 Non...

Страница 100: ...factors 33 Self supervision IRF 59 Sensor channels 10 11 12 Serial communication 60 Service 87 Service report 102 Signal output SO 10 11 12 45 Single pole power output 10 11 12 44 Software 89 Standar...

Страница 101: ...4 1080 Category Comment Query Complaint In case of feedback related to a specific product please name the product Product Description Initiator Issuer Company Country Telefax no e mail address If the...

Страница 102: ...___ Status _________________ Downloaded to the relay 0 1 0 18 QIRUPDWLRQ GHQWLILFDWLRQ QYLURQPHQW Hardware No _________________ MicroSCADA version _________________ Software No _________________ Proto...

Страница 103: ...RER 103 REX 52x RER 103 RER 123 RER 123 SMS IEC 103 Master REF RER 123 connected to X3 2 RER 103 connected to X3 3 RER 123 RER 103 RER 125 SPA ZC 22 SPA ZC 22 Fiber optic modem RS232C SMS SPA_IEC XQFW...

Страница 104: ...rnal IEC 60870 5 103 Class 1 buffer inside the REF 54_ unit can store up to 50 spontaneous events The interrogation events and the possible response messages that also are part of the class 1 data do...

Страница 105: ...supported in the REF 54_ In addition there are twelve more private class 2 ASDU frames defined The user can choose which one of these twelve measurand sets to use The measurand set number 1 17 can be...

Страница 106: ...zende Empfehlungen zur Anwendung in Verteilnetzstationen P Private definition W S Function type Note If stated as the signal type Ftyp corresponds with the unit function type Unit function type may be...

Страница 107: ...gnal from CUB1Cap A 85 0 2 1 CUB1Cap START signal from CUB1Cap dI1 stage P 182 1 1 1 1 9 CUB1Cap TRIP signal from CUB1Cap dI1 stage P 182 2 0 1 1 CUB1Cap ST_ALARM signal from CUB1Cap dI2 stage P 182 3...

Страница 108: ...RIP1 signal from f f St5 P 175 90 0 1 1 FREQ1ST5 START2 signal from f f St5 P 175 94 1 1 1 9 FREQ1ST5 TRIP2 signal from f f St5 P 175 91 0 1 1 FUSEFAIL Fuse failure P 253 83 1 1 1 9 INRUSH3 START sign...

Страница 109: ...START U1 P 180 2 1 1 1 9 PSV3St2 PSV3St2 START U1 P 180 3 1 1 1 9 PSV3St2 PSV3St2 TRIP U2 P 180 4 0 1 1 PSV3St2 PSV3St2 TRIP U1 P 180 5 0 1 1 PSV3St2 PSV3St2 TRIP U1 P 180 6 0 1 1 ROV1HIGH START signa...

Страница 110: ...1 open output P 242 202 0 1 1 COCB1 Breaker 1 close output P 242 203 0 1 1 COCB1 Breaker 1 opening time P 242 204 0 1 1 COCB1 Breaker 1 closing time P 242 205 0 1 1 COCB1 Breaker 1 command status P 24...

Страница 111: ...tion B 240 161 1 1 1 9 COIND2 Indication 2 position B 240 164 1 1 1 9 COIND3 Indication 3 position P 240 165 1 1 1 9 COIND4 Indication 4 position P 253 65 1 1 1 9 COIND5 Indication 5 position P 253 66...

Страница 112: ...aveform distortion measurement P 205 20 0 1 1 RPPXQLFDWLRQ IXQFWLRQV EVENT230 Customer event 0 1 P 252 1 0 1 1 EVENT230 Customer event 2 3 P 252 2 0 1 1 EVENT230 Customer event 4 5 P 252 3 0 1 1 EVENT...

Страница 113: ...g P 213 11 0 1 1 MEAI4 High alarm P 213 21 0 1 1 MEAI4 Low warning P 213 111 0 1 1 MEAI4 Low alarm P 213 121 0 1 1 MEAI5 High warning P 214 11 0 1 1 MEAI5 High alarm P 214 21 0 1 1 MEAI5 Low warning P...

Страница 114: ...ansmission values in response direction 20 Positive acknowledgement 21 Negative acknowledgement 7DEOH RPPDQGV RPPDQGV 6W W S QI 1XP 7 S 27 FPG 27 UHVS COCB1 Circuit breaker B 240 160 20 20 20 21 COCB2...

Страница 115: ...age data part Not available 7DEOH 5HFRPPHQGHG ODVV PHDVXUDQG VHWV 6HW 1R 6W XQFW S QIR 1XP 1XP GDWD 7 S DWD 1 Meas I 144 A 144 1 3 IL2 2 Meas I 145 A 145 2 3 IL2 U12 3 Meas I 146 A 146 4 3 IL1 U12 P Q...

Страница 116: ...connected to the function block Available measurements depend on the configuration e g phase voltage or phase to phase voltage DPSOH If the set No 11 is used the ASDU octets will look like in the fol...

Страница 117: ......

Страница 118: ...2 Substation Automation P O Box 699 FIN 65101 VAASA Finland Tel 358 10 22 11 Fax 358 10 224 1094 www abb com substationautomation 1MRS750527 MUM 09 2003...

Отзывы: