E. Troubleshooting

Ensure that breaker is installed correctly and all

 

terminal connections are torqued per instructions.

 

If the breaker fails to close check:

1.

2.

3.

4.

5.

For  overload  and  short  circuit  on  the  system. 

Handle  position  -  TRIPPED  -  reset  by  moving 

handle fully to OFF position and then to the ON 

position, see Figure 4.

Undervoltage  trip  is  supplied  with  rated 

voltage.

Shunt  trip  is  de-energized  and  no  trip  signal 

exists

Breaker trip unit settings are properly adjusted.

Installation instruction 

references:DEH40324 – 

Auxiliary switch & bell alarms. 

DEH40363 – Undervoltage 

release & shunt trip modules 

DEH40532  – Terminal lugs. 

Optional inter-

phase    

                                     

Barriers 

Applied accessorylabel to 

side of breaker

 

Bell al arm swit ch ID 

Outside auxiliary 

switch ID

Inside  auxili ary 

switch ID 

Shunt trip and 
Unde rvoltage modu le

Warning:

   Danger of electrical shock or injury. Turn off 

power supplies ahead of equipment before attempting 

to service.

Important::

   Danger  d’electrocution.  Couper 

l’alimenation avant d’effectuer toute action d’entretien.

Operate the breaker push to test button and toggle the 

handle several times, testing the mechanical operation 

of the device. If there are any signs of damage or if the 

mechanism  is  sluggish  or  sticky,  replace  the  breaker.  

For  abnormal  or  heavy  duty  conditions  refer  to  NEMA 

publication  AB4  and  for  recommended  maintenance 

practices NFPA70B.

G.

Storage

Store in a dry, dust free, environment protected from

 

corrosion.  Long term storage should be in the original

 

shipping carton.  Temperature range –40°C to +80°C.

H.

Accessories

For full details of the accessories and their application,

 

contact your local 

ABB

 

representatives. When

 

installing 

accessories

 

r

ead  the

 

accompanying

 

accessory 

installation instruction and

 

follow carefully

 

all cautions 

and warnings.

®

Fig 6. Typical Accessories. See Buylog for Details

 

  

4

1SQC930037M0201

,

 

DEH41

073

 

February 2020

 

 

ABB Inc. 

 

305 Gregson Drive

 

Cary, NC 27511. 

electrification.us.abb.com

  

 

We reserve the right to make technical 
changes or modify the contents of this 
document without prior notice. With 
regard to purchase orders, the agreed 
particulars shall prevail. ABB Inc. does not 
accept any responsibility whatsoever for 
potential errors or possible lack of 
information in this document. 

We reserve all rights in this document and 
in the subject matter and illustrations 
contained therein. Any reproduction or 
utilization of its contents – in whole or in 
parts – is forbidden without prior written 
consent of ABB Inc.  
Copyright© 2019 ABB  
All rights reserved 

 

GE is a trademark of GE. Manufactured 
by ABB Inc. under license from GE. 

If  technical  assistance  is  required  contact  your 

local ABB  sales  office.  In  the  US  call  ABB  Post 

Sales Customer Service, 1-888-437-3765.

F. Maintenance

Generally  no  maintenance  is  required  but  it  is 

recommended  that  the  breaker  be  cleaned  and 

inspected on an annual basis.

Note:  For  a  2  pole  breaker  there  are  no  auxiliary 

switch & bell alarm switch; For a 1 pole there are no 

accessories; Installation of an accessory in a 2 pole 

breaker is the same as a 3 pole breaker.

These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met 

in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that 

are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the ABB Company. The breaker is a sealed unit, 

which contains no user serviceable parts, tampering with seal will void warranty. 

Содержание Record Plus FB100

Страница 1: ... of applications All Record Plus TM circuit breakers are listed by Underwriters Laboratories to UL489 stand ard and by the CSA Standard C22 2 No 5 Record Plus TM circuit breakers are designed and manufactured to exceed our global customers high standards for performance reliability and quality Warning DANGER of Electrical shock or injury Ensure ALL electrical power supplies are OFF before installi...

Страница 2: ...mm 0 98 in B 98 1mm 3 86 in G 15 0mm 0 59 in C 15 0mm 0 59 in H 70 0mm 2 76 in D 129 7mm 5 11 in J 10 0mm 0 39 in E 17 5mm 0 69 in K 25 4mm 1 00 in Dimension for drill pattern escutcheon Fig 1 c 1 pole A 127 3mm 5 00 in F 5 1mm 0 20 in B 98 1mm 3 86 in G 15 0mm 0 59 in C 15 0mm 0 59 in H 70 0mm 2 76 in D 129 7mm 5 11 in J 10 0mm 0 39 in E 34 9mm 1 38 in K 25 4mm 1 00 in C Wire Terminal Connections...

Страница 3: ...d for convenienceof testing the mechanical trip operation of the breaker see Figure 3 The Push To Trip should be tested annually ON I I O O TRIPPED OFF 3 Fig 3 Circuit BreakerPush To trip Fig 4 Mechanical Operation of the Circuit Breaker Fig 5 Terminate wire as shown For FBL type circuit breakers Fig 3 Note Push to trip operationis same on all the three versionsof the breaker 1pole 2pole 3 pole L ...

Страница 4: ...s read the accompanying accessory installation instruction and follow carefully all cautions and warnings Fig 6 Typical Accessories See Buylog for Details 4 1SQC930037M0201 DEH41073 February 2020 ABB Inc 305 Gregson Drive Cary NC 27511 electrification us abb com We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase order...

Отзывы: