I

nstallation Procedure

1.

Access the optional module slots on the drive. Whenever 
necessary, refer to the 

Hardware Manual

 of the drive for 

instructions on removing any covers.

2.

Insert the module carefully into the slot

 

marked with 

“DDCS” (BCU control unit slot 4) on the control board 
until the retaining clips lock the module into position.

3.

Fasten the screws included in the package. Note that 
correct installation of the screws is essential for fulfilling 
the EMC requirements and for proper operation of the 
module.

4.

Lead the fiber optic cables from the external device to the 
appropriate channel(s) of the RDCO. Inside the drive, 
route the cables as shown in its 

Hardware Manual

. Make 

sure the cables are not kinked or laid against sharp 
edges. Observe colour coding so that transmitters are 
connected to receivers and vice versa. In case multiple 
devices are to be connected to one channel, they must 
be connected in a ring.

Technical data

Module types:

 RDCO-01(C), RDCO-02(C), RDCO-03(C), 

RDCO-04(C)

Degree of protection:

 IP 20

Ambient conditions:

 The applicable ambient conditions 

specified for the drive in its 

Hardware Manual

 are in effect.

Connectors:

20-pin pinheader

4 transmitter/receiver connector pairs for fiber optic cable. 
Type: Agilent Technologies Versatile Link. Communication 
speed: 1, 2 or 4 Mbit/s

Operating voltage:

 +5 V DC ±10%, supplied by the control 

unit of the drive.

Current consumption:

 200 mA max.

Electromagnetic immunity:

 IEC 1000-4-2 (limits: industrial, 

second environment); IEC 1000-4-3; IEC 1000-4-4; 
IEC 1000-4-6

Electromagnetic emissions:

 EN 50081-2; CISPR 11

Dimensions (mm):

34

95

20

30

 3AFE6

449

220

9 Rev 

B EN 

2013

-0

4-

29

www.abb.com/drives

www.abb.com/drivespartners