Operation Manual / Power2 340-H / High-pressure stage
3 Removal and installation / 3.2 Removing the high-pressure stage
© Copyright 2022 ABB. All rights reserved.
HZTL4054_EN
Rev.F
March 2022
Loosening the clamping nut
CAUTION
Incorrect procedure can make loosening impossible
If individual pressure screws are fully relieved, the pressure screws can be-
come compressed, making it impossible to loosen them.
u
Comply with the following steps for loosening the pressure screws.
CAUTION
Do not clean pressure screws
The pressure screws are equipped with a permanent sliding layer that must
not be removed. In case of non-compliance, it cannot be ensured that the
necessary tension force is reached.
u
Do not clean pressure screws.
u
Do not lubricate pressure screws.
If a screw jams, the previously loosened screw must be tightened again a little.
Fig. 14: Loosening the clamping nut
1. Working in a circle, break loose each pressure screw (≤ 20°).
2. Working in a circle, loosen each pressure screw by 45° in 4 rounds.
3. Working in a circle, loosen each pressure screw by 90° in 1…5 rounds until all of the pres-
sure screws have been relieved.
u
Loosen clamping nut by hand.
Page
32
/
114
Содержание PT003901
Страница 2: ......