Operation Manual / Power2 850-M / 4.1 Low-pressure stage
4
Disassembly and assembly
Page 28 / 49
© Copyright 2015 ABB. All rights reserved.
HZTL4062_EN
Revision -
December 2015
Control dimension after installing cartridge group
CAUTION
Control dimension outside the tolerance value
If the control dimension is out of tolerance, the cartridge group has not been
correctly installed and can be the cause of serious damage to the machine
or property.
Remove and reinstall the cartridge group.
Always replace jammed gasket rings with new ones.
If the control dimension is still out of tolerance, contact an ABB
Turbocharging Service Station.
Figure 24: Measuring control dimension X
After installing the cartridge group, the control dimension (X) must be measured.
Control dimension X
[mm]
63.0 ±0.09
Table 10: Control dimension X