5
Maintenance
5.1
General
Web/strip Tensiometer Systems with Pressductor
®
load cells are extremely reliable and do not
require daily servicing. As a preventive measure, checks should be done periodically on all parts
subject to mechanical wear.
5.2
Preventive Maintenance
Check mounting screws and tighten if necessary.
The gaps between load cell and plates should be checked to ensure that they do not get clogged
with dirt, causing shunt force past the load cell. Clean the gaps with compressed air if necessary.
The cable between the load cell and the junction box is subjected to possible damage and should
be checked and replaced if necessary.
5.3
Spare Parts
Users are recommended to keep the following spare parts in stock:
•
One load cell of correct type and size.
•
One connector complete with cable (for PTFL 101A and PFTL 101B).
Table 3 Ordering numbers for Load Cell PFTL 101
Description
Type
Nominal load
(kN)
Ordering numbers
Load cell
PFTL 101A
0,5
3BSE004160R1
Load cell
PFTL 101A
1,0
3BSE004166R1
Load cell
PFTL 101A
2,0
3BSE004172R1
Load cell
PFTL 101AE
0,5
3BSE004211R1
Load cell
PFTL 101AE
1,0
3BSE004212R1
Load cell
PFTL 101AE
2,0
3BSE004213R1
Load cell
PFTL 101AER
0,5
3BSE023010R1
Load cell
PFTL 101AER
1,0
3BSE023011R1
Load cell
PFTL 101AER
2,0
3BSE023012R1
Pressductor PillowBlock Load Cells, Horizontal Measuring PFTL 101, User Manual
5 Maintenance
24
3BSE009965R0401 en Rev E