MN1949WEN
Input / Output 3-5
3.1.3 Analog outputs
Four independent bipolar analog outputs.
Output range: ±10 V (±0.1%).
Resolution: 16-bit.
Output current: 10 mA maximum.
Update frequency: 1 kHz.
All of the outputs may be used as general purpose analog outputs - see the
DAC
keyword in
the Mint help file. The analog outputs may be used to drive loads of 1 k
Ω
or greater. Shielded
twisted pair cable should be used. The shield connection should be made at one end only.
Figure 3-7: AOUT8/16 analog output circuit
When the MotiFlex
e
100 is connected to Mint WorkBench, the analog output value
(expressed as a percentage) can be viewed using the Spy window's Monitor tab. The
DAC
command can be used in the command window to set the value of an analog output as a
percentage of full scale. For example, assuming the card is mounted in slot 1, the command
DAC(8) = 50
will set analog output 8 to +50% (approxi5 V). See the Mint help file
for details.
3.1.4 Power consumption
The maximum overall power consumption of the Analog I/O option card is 2.8 W. See the
main MotiFlex
e
100 installation manual (MN1943WEN) for further details about the option
slots’ power supply and derating information.
TL084
4
5
-15 V
+15 V
AOUT8/16
AGND
OPT-MF-001 Analog I/O
-
+
Mint
DAC(8)
DAC(16)
±100%
or
Содержание OPT-MF-001
Страница 1: ...MN1949 Analog I O Option ...
Страница 2: ......
Страница 4: ...ii Contents MN1949WEN ...
Страница 14: ...3 6 Input Output MN1949WEN ...
Страница 15: ...MN1949WEN Input Output 3 7 ...
Страница 16: ...3 8 Input Output MN1949WEN ...
Страница 18: ...Comments MN1949WEN Thank you for taking the time to help us ...
Страница 19: ......