![ABB MicroFlex e150 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/abb/microflex-e150/microflex-e150_quick-installation-manual_2742007.webp)
Quick Installation Guide – MicroFlex e150 7
24 V DC control supply and filter
MicroFlex e150 requires a 24 V DC (20-30 V DC) 1 A supply to power
the control electronics.
Connect the control supply at connector X2.
A fused DC supply should be provided for the MicroFlex e150. If other
devices are to be powered from the same 24 V supply, a filter (catalog
number FI0014A00) should be installed to isolate the MicroFlex e150
from the rest of the system. Alternatively, a ferrite sleeve may be
attached to the supply cable near connector X2.
Safe Torque Off (STO) inputs
24 V DC (12-30 V DC) must be applied to both STO inputs
to allow the drive to operate. SREF is common to both
inputs.
Digital I/O
24 V DC (12-30 V DC) general purpose digital inputs and
outputs.
Analog I/O
An analog input can be used to receive a ±10 V demand
signal from a motion controller.
The ±10 V analog output can be used to control external
devices.
0V
24V
X2
X3
STO1
STO2
SREF
SREF
X3
DOUT2+
DOUT2-
Status-
DOUT1+
DOUT1-
DIN2+
DIN2-
DIN3+
DIN3-
DIN1+
DIN1-
DIN0+
DIN0-
X4
AIN1-
AIN0-
AIN0+
AIN1+
Shield
Shield
AGND
AOUT0
Содержание MicroFlex e150
Страница 12: ...12 Quick Installation Guide MicroFlex e150 ...
Страница 22: ...22 Kurzinstallationsanleitung MicroFlex e150 ...
Страница 32: ...32 Guía de instalación rápida MicroFlex e150 ...
Страница 42: ...42 Guide d installation rapide MicroFlex e150 ...
Страница 52: ...52 Guida d installazione rapida MicroFlex e150 ...
Страница 62: ...62 Snabbinstallationshandbok MicroFlex e150 ...
Страница 72: ...72 快速安装指南 MicroFlex e150 ...