2CSG445053D0201 [ V. 1.00]

 

 

1

/

10 

 

 

COMMISSIONING GUIDELINE

 

M4M Firmware update 

 

Getting started

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

Содержание M4M

Страница 1: ...2CSG445053D0201 V 1 00 1 10 COMMISSIONING GUIDELINE M4M Firmware update Getting started ...

Страница 2: ...ial and tools needed 3 2 Initial settings on M4M device 3 2 1 M4M Modbus RTU M4M 20 Modbus M4M 20 I O M4M 20 Rogowski M4M 30 Modbus M4M 30 I O M4M 30 Rogowski 3 2 2 M4M Ethernet M4M 20 Ethernet M4M 30 Ethernet 4 3 FW update procedure via EPiC desktop 5 ...

Страница 3: ...hernet for both M4M 20 and M4M 30 ver sions 2 1 M4M Modbus RTU M4M 20 Modbus M4M 20 I O M4M 20 Rogowski M4M 30 Modbus M4M 30 I O M4M 30 Rogowski A Check that Modbus RTU cable connected to the ABB power meter is cor rectly connected in particular make sure that W1 A W2 B TIP in case the device is not communicating re cable the device by switching terminals hence W1 B W2 A B Steps to set Modbus RTU ...

Страница 4: ...device go to HOME Configura tion Communication Modbus TCP IP Parameters that can be set are DHCP IP address Subnet mask Gateway and TCP port In the DHCP section select between Enable and Disable In the IP address section select the desired address of the device or read the current IP address if the DHCP support is enabled TIP In case of ABB cloud access point DHCP on M4M should be disabled as defa...

Страница 5: ...vice in the RS 485 architecture e g PLC the master should be disabled in order to use EPiC desktop and perform the FW update B Open EPiC desktop in the Scan tab C Configure the scanning via communication protocol 1 Via Modbus RTU M4M Modbus Click on Configure under Serial port Select port name baudrate parity slave addresses of all devices connected via Modbus RTU to be updated Press OK ...

Страница 6: ...on Configure under Ethernet In the section IP addresses insert the IP address of M4M Ether net in the list of IP addresses to be scanned It is possible to either add IP addresses one by one Use IP address list or input IP ad dress range Use IP address range Press Ok ...

Страница 7: ... on Scan E EPiC desktop allows to visualize the product related pages including dashboard and Modbus map reading via Classic View In the Information section of the Dashboard it is possible to check what is the firmware version currently installed on M4M F Click on Tools ...

Страница 8: ...irmware update option in order to upload the FW version previously downloaded from the ABB Library here Please extract the enc file from the downloaded zip I Please click on the Select file from Computer option and select the enc related to the latest FW version of M4M ...

Страница 9: ...th the M4M during the FW update process in or der to have a successful update K A loading bar will inform regarding the status of the FW update After reaching the 100 M4M will start the rebooting process for few minutes while checking the new firmware The screen will turn black and the red LED lights will be on Please do not unplug the M4M s auxiliary power sup ply during this operation ...

Страница 10: ...M4M FIRMWARE UPDATE 10 10 L As the FW update is completed successfully a banner will appear on Ekip Connect to inform the user ...