Product description
Product manual 2TMD041600D0130
│
8
5.2
Terminal description
No.
Description
1
Station
Select switch to set the address of the default outdoor station.
2
X10 X1
Selector switches to set the address (tens and units digits) of the indoor station.
X200 X100
Dip switches to set the address (hundreds digits) of the indoor station.
3
Master/slave function
Only one indoor station in an apartment can be set to "Master" (ON=Master). All other indoor
stations in the same apartment must be set to "Slave (OFF=slave).
4
Terminal resistor
In video installations or mixed audio and video installations, the switch must be set as ON at
the last device of the bus line.
5
a b = BUS connection
doorbell connection
DC GND =Additional power supply
6
Connector to an induction loop
4
2
3
1
5
24