5.3
Electrical Characteristics
Power Supply:
115/230Vac one-phase ±15% 50/60Hz (adjustable by the user)
Protection fuse:
T10AL250V
Maximum power consumption: 800VA
5.4
Environmental Characteristics
Operating temperature
+5°C…+45°C
Storage temperature
-5°C…+60°C
Relative humidity
0%...95% without condensation
5.5
Input/Output
5.5.1
Test connector
The TS3 input and output connections are available to the user by means of the frontal “Main Connector” (see chapter
5.7
),
to be connected at the extension cable and/or at the test cable (see chapter
4
), both supplied with the test device. On this
connector and consequently on the test cable, the following are available:
5.5.1.1
Generated current signal
Trip Unit
In relè
Itest
Scale
Tolerances I test max
PR1
250 … 6300 A
0.1 … 15 In
0…0.8In 0.8…10In 10…15In
3% f.s
94.5 KA
AR1/S1
250 … 6300 A
0.1 … 15 In
0…0.8In 0.8…10In 10…15In
3% f.s
94.5 KA
S2
250 … 6300 A
0.1 … 15 In
0…0.8In 0.8…10In 10…15In
3% f.s
94.5 KA
PR11x
250 … 6300 A
0.1 … 12 In
0…0.4In 0.4…5.In
5…12.In
3% f.s
75.6 KA
PR12x
400 … 6300 A
0.1 ... Ix(*) In
0…4830A
4830…48300A
3% f.s
48.3 KA
PR23x
400 … 1600 A
0.1 …15In
0…5540A
5540…24000A
3% f.s
24 KA
PR33x
200 … 1600 A
0.1 …15In
0…5540A
5540…24000A
3% f.s
24 KA
Table 1
Accuracy specification
Note1
: the max value to generable current
Itest
is indicated on the display.
Note2
:
=
In
15
,
relè
In
max
test
I
min
Ix(*)
Example :
If the
In relè is 6300 A, being the Itest max 48300 A, then the Itest max will be 48000/ 6300 = 7.66 In