![ABB IRC5 with FlexPendant Скачать руководство пользователя страница 183](http://html.mh-extra.com/html/abb/irc5-with-flexpendant/irc5-with-flexpendant_operating-manual_5099183.webp)
Information
Action
When all points are defined you can save
them to file, which enables you to reuse
them later. On the
Positions
menu, tap
Save
.
6
For further information see
lated result good enough? on page 183
Tap
OK
. The
Calculation Result
dialog box
will now be displayed, asking you to cancel
or to confirm the result before it is written
to the controller.
7
How to define elongator points
This procedure describes how to define the orientation of the tool frame by
specifying the direction of the z and/or x axis. You need to do this only if you the
tool orientation should differ from that of the robot base. The tool coordinate system
by default resembles the coordinate system of tool0, as illustrated in
the tool center point on page 185
.
Action
Without changing the orientation of the tool, jog the robot so that the reference world
point becomes a point on the desired positive axis of the rotated tool coordinate system.
1
Tap
Modify Position
to define the point.
2
Repeat step 1 and 2 for the second axis if it should be defined.
3
Is the calculated result good enough?
The
Calculation Result
dialog box displays the calculated result of the tool frame
definition. You have to confirm that you accept the result before it can take effect
in the controller. The alternative is to redo the frame definition in order to achieve
a better result. The result
Mean Error
is the average distance of the approach
points from the calculated TCP (tool center point).
Max Error
is the maximum error
among all approach points.
It is hard to tell exactly what result is acceptable. It depends on the tool, robot type
etc. you are using. Usually a mean error of a few tenths of a millimeter is a good
result. If the positioning has been undertaken with reasonable accuracy the result
will be okay.
As the robot is used as a measuring machine, the result is also dependent on
where in the robot’s working area the positioning has been done. Variation of the
actual TCP up to a couple of millimeters (for large robots) can be found between
definitions in different parts of the working area.The repeatability of any following
TCP calibrations will thus increase if these are done close to the preceding ones.
Note that the result is the optimal TCP for the robot in that working area, taking
into account any discrepancies of the robot in the configuration at hand.
Tip
A common way to check that the tool frame has been correctly defined is to
perform a reorientation test when the definition is ready. Select the reorient
motion mode and the tool coordinate system and jog the robot. Verify that the
tool tip stays very close to the selected reference point as the robot moves.
Operating manual - IRC5 with FlexPendant
183
3HAC050941-001 Revision: G
© Copyright 2018 ABB. All rights reserved.
5 Programming and testing
5.5.4 Defining the tool frame
Continued
Содержание IRC5 with FlexPendant
Страница 1: ...ROBOTICS Operating manual IRC5 with FlexPendant ...
Страница 2: ...Trace back information Workspace R18 2 version a9 Checked in 2018 10 09 Skribenta version 5 3 008 ...
Страница 14: ...This page is intentionally left blank ...
Страница 120: ...This page is intentionally left blank ...
Страница 146: ...This page is intentionally left blank ...
Страница 240: ...This page is intentionally left blank ...
Страница 286: ...This page is intentionally left blank ...
Страница 294: ...This page is intentionally left blank ...
Страница 298: ...This page is intentionally left blank ...
Страница 304: ......
Страница 305: ......