Action
Situation
Remove the calibration tool, if it is installed,
and restart the calibration procedure from
the beginning. See
.
The RobotWare program is terminated with
PP to Main
.
If the calibration tool is in contact the robot
axis needs to be jogged in order to release
the calibration tool. Jogging the axis in wrong
direction will cause the calibration tool to
break. Directions of axis movement is shown
in
Calibration movement directions for all
Axis Calibration with SafeMove option
To be able to run Axis Calibration SafeMove needs to be unsynchronized. The Axis
Calibration routine recognizes if the robot is equipped with SafeMove and will force
SafeMove to unsynchronize automatically.
However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine.
Safety controller not synchronized - SafeMove message
Note
Action
SafeMove generates the message "Safety control-
ler not synchronized".
xx1500002480
1
Confirm unsynchronized state by pressing
Ac-
knowledge
to continue Axis Calibration proced-
ure.
2
Restart Axis Calibration procedure by pressing
Play
.
3
Continues on next page
806
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued
Содержание IRB 6700 - 150/3.20
Страница 1: ...ROBOTICS Product manual IRB 6700 ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 46: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 786: ...This page is intentionally left blank ...
Страница 812: ...This page is intentionally left blank ...
Страница 836: ...This page is intentionally left blank ...
Страница 838: ...This page is intentionally left blank ...
Страница 845: ......