Note
Action
xx0200000023
3
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the sec-
tion
The unit is sensitive to ESD on page 32
Remove SMB/BU box by unscrewing the attach-
ment screws.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
4
Lift the
SMB/BU unit
out of its box and disconnect
the battery cable.
5
Remove the velcro strap that holds the battery.
6
Shown in figure
Remove the
SMB battery.
Battery includes protection circuits. Only replace
with a specified spare part or with an ABB- ap-
proved equivalent.
7
Refitting, battery
Use this procedure to refit the SMB battery.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
1
xx0200000023
2
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the sec-
tion
The unit is sensitive to ESD on page 32
Continues on next page
Product manual - IRB 6620
171
3HAC027151-001 Revision: T
© Copyright 2006-2018 ABB. All rights reserved.
3 Maintenance
3.4.8 Replacing the SMB battery
Continued
Содержание IRB 6620
Страница 1: ...ROBOTICS Product manual IRB 6620 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 176: ...This page is intentionally left blank ...
Страница 338: ...This page is intentionally left blank ...
Страница 350: ...This page is intentionally left blank ...
Страница 352: ...This page is intentionally left blank ...
Страница 358: ......
Страница 359: ......