Removing cable harness in base
Use this procedure to remove the cable harness in the base.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
xx0900000014
Disconnect the following connectors on the
base cover
:
•
R1.CP/CS
•
R1.MP
•
R1.CBUS (if used)
Tip
Do not remove the
R1.SMB-connector
and
air hose connector
at this stage. It will be
easier to remove these two when the cover
base has been removed.
2
Parts:
•
A: R1.CP/CS
•
B: R1.MP
•
C: Air hose connector
•
D: Position of R1.CBUS (if used)
•
E: R1.SMB
A
B
C
xx0800000456
A Base
B Cover base
C Attachment screws
Remove the
cover base
.
3
Disconnect connectors on the brake release
unit:
•
X8
•
X9
•
X10
4
Continues on next page
198
3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued