Note
Action
Remove the 4x hexagon bolt with flange M6x20
holding the front plate, and remove the plate and
the gasket.
6
Refitting
Note
Action
Tightening torque 4 Nm
.
Refit the front plate and the gasket using the 4x
hexagon bolt with flange M6x20. (if needed, replace
the gasket)
1
Refit the ejector unit from the inside.
2
Tightening torque 4 Nm.
Refit all the nuts for the air nozzles, pressure guard
cap and the pressure guard nut.
3
Use standard tools.
Refit the filters using the 2x hexagon socket head
cap screw M8x35.
4
Reconnect the air supply, vacuum hoses and signal
cable from the ejector unit.
5
Replacement of base cover gas-
ket on page 167
Refit the base cover.
6
228
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacement of ejector unit
Continued