2.1.2. Charge Pole
A
Door to ACM
B
Emergency button
C
Charge state indicator light (beacon)
D
Distance sensor
E
Pantograph
F
WiFi communication unit
G RFID unit (if installed, optional)
2.2. Description of user interface
There are three indicator lights (C) at the Charge Pole that serve as an information for the bus
driver:
Color
State
Charge status
Continuous
Ready to charge
Blinking
Initializing
Continuous
Charge complete
Blinking
Charging
Continuous
Error
Under the beacon (C) there is a red Emergency button (B). This Emergency button can be
used only in an emergency situation. When pushing this Emergency button it will immediately
stop the charging process and cut off the DC power from the charger. See also section
on page 16.
2.3. Charger system configurations
The HVC Opportunity Charger is built up with a modular architecture. There are three HVC
Opportunity Charger systems available, depending on the DC output power:
Charger system
Power Cabinet(s)
DC output power
HVC 150P Opportunity
Charger
HVC 150
150 kW
HVC 300P Opportunity
Charger
HVC 150 and HVC 150S
300 kW
HVC 450P Opportunity
Charger
HVC 150 and 2x HVC 150S
450 kW