Wet cleaning using external water-pressure vessel (XC3)
Operating state prerequisites for wet cleaning XC3
NOTICE
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisites must be fulfilled:
Engine load 50 ... 85%
Start of cleaning cycle in accordance with following description for
wet cleaning operation with XC3.
Operating procedure for compressor wet cleaning with XC3
The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
Remove sealing plug (X).
Fill vessel with required volume of clean water (see table Cleaning pa-
rameters).