Operation Manual / TPL76-C
Commissioning
3
Oil supply
3.1
Page 35
© Copyright 2016 ABB. All rights reserved.
Febr
uar
y 2016
H
ZT
L2485_
EN
R
ev
is
ion
C
Lubricating oil temperature at inlet
CAUTION
Machine damage
If the oil temperature at the oil inlet exceeds the admissible range, this
may lead to engine damage.
Observe oil temperature at the oil inlet according to the following
table.
Status for operation
Oil temperature at inlet
T
oil,inlet
[°C]
Permissible
30 … 80
Temporarily permissible (< 1h) -> alarm
> 80
Not permissible -> stop engine
> 85
Not permissible -> Do not start engine (before
starting: preheat oil)
< 30
Lubricating oil temperature at outlet
The oil temperature at the outlet is mainly dependant on:
Lubricating oil temperature and pressure at the oil inlet
Engine load and turbocharger speed
Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the
following table. The specified oil outlet temperature is to be considered as
alarm value for the turbocharger operation and must be monitored
according to the current regulations.
Status for operation
Oil temperature at outlet
T
oil,outlet
[°C]
Permissible
≤
130
Temporarily permissible -> alarm
> 130
Not permissible -> stop engine
> 150
If the turbocharger was operated for a longer period of time outside of the
admissible range, ABB Turbo Systems recommends to have the
turbocharger inspected by an ABB Turbocharging Service Station.