Operation Manual / A150-M56/66/57/67 - A155-M..
7 Periodic maintenance work / 7.4 Cleaning components mechanically
© Copyright 2022 ABB. All rights reserved.
HZTL4032_EN
Rev.S
February 2022
(see Fig. 32: Cleaning the filter silencer
Dismantling and cleaning the cover grid (81266)
u
Loosen and remove lock nuts (81273).
u
Loosen and remove screws (81272) to the connecting rods (81269).
Have damaged connecting rods replaced by a Turbo Systems service station.
u
Remove connecting rods (81269).
u
Remove and clean cover grid (81266).
Cleaning the absorption segments (81136)
u
Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
ments (81136).
u
Clean the absorption segments.
When cleaning, note that the absorption segments may only be cleaned lightly with pres-
surized air, a soft brush or a moist cleaning cloth.
u
Have any heavily contaminated absorption segment replaced by a Turbo Systems service
station.
Fitting the filter silencer
u
Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u
Bend the sheet-metal coverings (81137) back to their original shape and insert into the
slotted guides in the filter silencer body (81135).
u
If the cleaning container is present on the filter silencer: Reinstall the water injection pipe.
Page
71
/
198
Содержание HT613076
Страница 2: ......