Operation Manual / A130-M.. - A145-M..
9 Dismantling and fitting / 9.18 Installing the air inlets
© Copyright 2022 ABB. All rights reserved.
HZTL4031_EN
Rev.P
February 2022
9.18
Installing the air inlets
Fig. 62: Installing the air inlets
Product
Size
Tightening torque [Nm]
A130
M12
60
A135
M12
60
A140
M12
60
A145
M12
60
Table 45: Tightening torque (72020)
1. Secure lifting gear to filter silencer (81000).
2. Fit a new O-ring (81010) to the filter silencer (81000) or a new O-ring (82010) to the air
suction branch (82000).
3. Fit the filter silencer (81000) or air suction branch (82000) with the V-clamp (72020).
4. Observe tightening torque.
Page
114
/
149