![ABB HT596239 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/abb/ht596239/ht596239_operation-manual_3417758042.webp)
Operation Manual / 4 Product description / A100-M axial
2 Removal and installation / 2.3 Installing the turbocharger
© Copyright 2020 ABB. All rights reserved.
HZTL4033_EN
Rev.E
May 2020
2.3
Installing the turbocharger
WARNING
Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all dur-
ing removal and installation, it may tip over and cause severe injury to per-
sonnel or accidents resulting in fatalities.
u
Support the turbocharger at a suitable location.
u
Secure with lifting gear wherever possible.
Fig. 9: Turbocharger suspension points
u
If present: Remove insulation segment on the bearing casing.
u
Attach lifting gear to the suspension lug of the bearing casing and the turbine-end foot.
u
Remove the covers from the oil connections.
u
Align turbocharger and place on bracket.
Page
12
/