Operation Manual / 4 Product description / A100-M axial
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
© Copyright 2019 ABB. All rights reserved.
HZTL4033_EN
Rev.D
December 2019
6.4.5
Wet cleaning with external water pressure vessel
Operating state prerequisites for cleaning the compressor
On V-engines with several turbochargers per engine, parallel cleaning of both turbochargers
is recommended. This cleaning process is faster and reduces the risk of surging of the tur-
bocharger.
To carry out the cleaning operation checked and recommended by ABB Turbo Systems, the
following prerequisites must be fulfilled:
¡
Engine load 50 ... 85 %
u
Start the cleaning operation according to the following description.
Operation of compressor wet cleaning
Fig. 23: Operation of water pressure vessel
Operation of the water pressure vessel
u
The
prerequisites for operating state for cleaning the compressor with XC3
must be ful-
filled
before the cleaning.
u
Screw out sealing plug (
X
).
u
Fill container with pure water.
u
Screw in sealing plug (
X
).
u
Push valve activator (
Y
) against the spring and hold for
10
to
15 seconds
until the whole
volume of water is injected.
Page
43
/
114