Operation Manual / 4 Product description / A130-H.. - A140-H
8 Dismantling and fitting / 8.15 Installing the compressor casing
© Copyright 2020 ABB. All rights reserved.
HZTL4030_EN
Rev.F
February 2020
8.15
Installing the compressor casing
Fitting the wall insert and the diffuser
Fig. 47: Fitting the wall insert and the diffuser
Product
Size
Tightening torque [Nm]
A130
M6
8
A135
M6
8
A140
M6
8
Table 38: Tightening torque (79041)
1. Always replace the O-ring (77005) (see section Spare parts).
2. Install the wall insert (77000) into the compressor casing.
3. Secure the diffuser (79000) with fixing discs (79040) and screws (79041).