Fitting the wall insert
Fig. 57: Fitting the wall insert
Part number
A170-M
A175-M
72011
M20
580 Nm
M24
1000 Nm
Table 42: Tightening torque (72011)
1. Remove lifting device (90190/90195).
2. Slide wall insert (77000) into compressor casing up to stop and remove guide stud
(90319).
3. Secure wall insert with screws (72011) and washers (72008).
For assembly of the alternative air inlet, see section
Removing / Installing air-inlets
.