Operation Manual / TPL65VA32/33
Disassembly and assembly
8
Installing cartridge group
8.9
Page 97
© Copyright 2015 ABB. All rights reserved.
Sept
em
ber
2015
H
ZT
L2464_
EN
R
ev
is
ion
C
Measure and note the axial clearance (A) (see the section on axial
clearance).
CAUTION
Clearances out of tolerance
Clearances out of tolerance and excessively worn components can be
the cause of serious damage to machinery and property.
Have components assessed and, if necessary, replaced by an ABB
Turbocharging Service Station.
Connect oil pipes and all air lines in accordance with engine builder’s
instructions.
Version with compressor wheel cooling system
Fit the air supply line. (Also see the chapter Preliminary remarks /
Layout and functioning.)
Fit the filter silencer or air suction branch.
Fit the insulation.