Operation Manual / 4 Product description / A130-M.. - A145-M..
8
Dismantling and fitting
Page 99 / 117
© Copyright 2016 ABB. All rights reserved.
HZTL4031_EN
Revision D
June 2016
8.18
Installing the gas outlet flange
Figure 50: Installing the gas outlet flange
1. If present: Insert the metal C-ring (57003) into the turbine casing (51000) and secure with
high-vacuum grease.
2. Install the gas outlet flange (57002) in the turbine casing.
3. Measure radial clearance (R) (see chapter Radial clearances N and R).
8.19
Installing the gas outlet casing
Figure 51: Installing the gas outlet casing
Part number
A130
A135
A140
A145
51009
M8
20 Nm
M10
40 Nm
M12
65 Nm
M12
65 Nm
Table 45: Tightening torque (51009)
1. Insert a new gasket (61002) into the gas outlet casing (61001).
2. Attach the lifting gear to the gas outlet casing (61001) and position the gas outlet casing in
the correct position on the turbine casing (51000).
3. If present: Fit the support (61301).
4. Fit and tighten the hexagon nuts (51009).