Operation Manual / TPS44-F.. - TPS61-F..
Maintenance
5
Cleaning the compressor during
operation
5.2
Page 58
Apr
il 20
15
H
ZT
L24
12_
EN
R
ev
is
ion E
Wet cleaning compressor using external water pressure vessel (XC1)
NOTICE
These instructions for wet cleaning apply only when cleaning is carried
out with clean water and the enginebuilder permits the process.
NOTICE
Supplying water from the externally mounted water vessel is suitable
only for those applications where a negative pressure exists in front of
the compressor wheel (not used for: blowers connected in front of the
compressor or high-pressure compressor stages with two-stage
charging).
Operating state prerequisites for cleaning compressor with XC1
NOTICE
To be able to carry out a satisfactory cleaning process that has been
tested and is recommended by ABB Turbo Systems, the following
prerequisites must be fulfilled:
Run engine at load from 50 … 85 %.
Start cleaning cycle according to following description Wet cleaning
operation with XC1.
5.2.1