Operation Manual / 2 Safety / A130 - A155
1
Safety
Page 14 / 18
WARNING
Burst protection and insulation
Operation without burst protection and insulation or with the wrong
combination of burst protection and insulation can cause serious injuries to
persons or even fatal accidents.
Only operate the turbocharger with burst protection fitted and insulation
fitted in one of the following, permitted variants.
Figure 5
Variant A
Insulation (01) with integrated burst protection from ABB Turbo Systems.
Variant B
Burst protection (03) and insulation (02) from ABB Turbo Systems.
Variant C
Burst protection (03) from ABB Turbo Systems with appropriate insulation from the
enginebuilder.