![ABB HT537476 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/abb/ht537476/ht537476_operation-manual_4184455043.webp)
Operation Manual / TPR56-F + TPR61-F
4 Operation / 4.4 Speed measurement
© Copyright 2018 . All rights reserved.
HZTL2490_EN
Revision D
May 2018
4.4.3
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Risk of burning. During operation, the cable connector and the speed
sensor can reach temperatures exceeding 100 °C.
u
Wear safety gloves when removing the cable connector and speed
sensor.
Wear safety gloves to protect against thermal hazards.
u
Reduce engine performance to the idling speed, then stop the engine.
u
Switch off the lubricating oil supply to the turbocharger.
u
Disconnect the cable connector from the speed sensor.
u
Screw out defective speed sensor.
u
Screw in a new speed sensor to the stop.
u
Observe the tightening torque (see the table of tightening torques in
the chapter entitled Disassembly and assembly).
NOTICE
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and does not require
any additional gasket for assembly.
u
Connect cable connector to speed sensor.
u
Switch on lubricating oil supply to turbocharger.
Page
41
/
79