Commissioning
Product manual 2TMD041800D0018
│
21
8.8.2
Local settings
No.
Function
1
Device No
Range is 1...32.
2
Call mode
Toggles the call mode between "Physical address" (default) and "Logical address".
3
The 2nd lock
Releases the secondary lock on the outdoor station if the function is enabled.
4
Security mode/Compatible mode
The guard unit works in "Security mode" by default to guarantee high security (switch is set to
"off"). In this mode, the certificate issued by the management software must be set up on the
guard unit before use.
If there is no management software, the guard unit works in "Compatible mode" to work
normally. (switch is set to "on").
5
Clear all data
This function is only available within 120 s after the indoor station is powered on. All data
including user settings and engineering settings will be reset to the factory defaults
Содержание H8303
Страница 1: ...2TMD041800D0018 20 06 2019 Product manual ABB Welcome IP H8303 Guard unit H8303 02 Guard unit ...
Страница 10: ...Mounting Installation Product manual 2TMD041800D0018 10 7 2 Mounting ...
Страница 12: ...Commissioning Product manual 2TMD041800D0018 12 2 Accept licensing terms ...
Страница 13: ...Commissioning Product manual 2TMD041800D0018 13 3 Set date and time ...
Страница 46: ...Operation Product manual 2TMD041800D0018 46 ...