background image

 

EN

 

 

Electrical connections

 

 

Terminal connections

 

0 V

 

Supply 0 V

 

R+ 

 

24 VDC

 

S+ 

 

Unlock signal (solenoid) +24 VDC in

 

11/12

 

Safety interlock and lock monitoring circuit

 

21/22

 

Safety interlock and lock monitoring circuit

 

44

 

Guard opened 24 VDC out

 

34

 

Guard unlocked 24 VDC out

 

ER

 

External Reset Signal

 

LED Diagnostics

 

There are two LED indicators on the GKey switch.

 

Safety lock state 

 

LED 1 (Green/Yellow)

 

Comment

 

Guard Open

 

OFF

 

 

 

Guard  Locked

 

Steady green

 

Safety outputs ON

 

Guard  Unlocked

 

Flashing green

 

 

Guard  Misaligned/

 

Wrong actuator

 

Alternate flashing green/

 

yellow

 

 

Fault

 

Steady yellow

 

See Reset instructions (in complete original instructions)

 

Problem with reset procedure

 

Steady green and yellow

 

 

Make sure the RFID actuator is in contact with GKey (guard 

closed) and cycle the power.

 

Solenoid state

 

LED 2 (Red)

 

Energized

 

ON

 

De-energized

 

OFF

 

Maintenance

 

Every month: Check correct operation of all circuits and the Lock function. If any part of the GKey product displays mechanical damage, 

then remove and replace.

 

Every six months: Isolate power and remove cover. Check screw terminal tightness and check for signs of moisture ingress. Re-check 

according to the installation instructions in this manual.

 

Lock closed

 

and locked

 

Re

d

 

G

re

en

 

Ye

llo

w

 

Error

 

reset

 

Front

 

handle

 

Rear

 

handle

 

Escape release

 

button

 

Отзывы: