![ABB FSO-21 Скачать руководство пользователя страница 447](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728447.webp)
Parameters 447
Active high
Active state of the output is high voltage.
SAFEIO.76 DO X114:9 logic
state
Sets the logic state of digital output X114:9.
Active low
Active state of the output is low voltage.
Active high
Active state of the output is high voltage.
41
SBUSGEN
General parameters for safety fieldbusses
SBUSGEN.
01
SBUS activity and
version
Activates or deactivates the safety fieldbus.
Disabled
Disabled
Deactivates the safety fieldbus.
Version 1
Activates version 1 of the safety fieldbus.
SBUSGEN.
06
Safety fieldbus
speed scaling
Sets the rpm value that corresponds to
20000 for safety fieldbus communication.
1500.0 rpm
0.10…30000.0
SBUSGEN.
07
Safety fieldbus
position scaling
Sets the scaling value for the shaft rotation
(base unit 1/1000 grad). If this parameter is
set to
1000
, value
400
in the safety fieldbus
equals to one full shaft revolution.
Note
: This parameter is relevant only when
an encoder is used.
1.0
0.01…30000.0
SBUSGEN.10 STO indication
passivation
Sets the type of the event that the FSO
module generates when the FSO module is
passivated
due to safety fieldbus problems.
None
No event generated
Fault
Fault generated
Warning
Warning generated
Event
Pure event generated
41
PROFIsafe
Parameters for PROFIsafe
PROFIsafe.11 PROFIsafe
F_Dest_Add
Sets the PROFIsafe destination address for
FSO which is used in the safety
communication network.
Note
: This address must be the same as is
set in the F-Parameters for the PROFIsafe
module properties (F_Dest_Add). For more
information, see section
on page
.
1
1…65534
PROFIsafe.
12
PROFIsafe telegram
type
Shows the PROFIsafe telegram type.
0x221
PROFIsafe telegram 0x221 (545).
Corresponds to profile ABB_PS1 in the GSD
file. See section
on page
.
Index
Name/Value
Description
Factory
default
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...