![ABB FSO-12 Скачать руководство пользователя страница 362](http://html.mh-extra.com/html/abb/fso-12/fso-12_user-manual_2726362.webp)
362 Fault tracing
1)
If you select Fault for parameter
, the FSO module generates a
warning at the limit hit, and a fault only after the system is at the Safe state.
Note:
If you select None for parameter
, the FSO module generates
no event when it detects a limit hit.
User-selectable events for safety fieldbus failures
The table below lists user-selectable events related to safety fieldbus failures.
1)
If you select Fault for parameter
, the FSO module generates a
warning at the passivation, and a fault only after the system is at the Safe state.
Note
: If you select None for parameter
, the FSO module generates
no event when it detects a failure in the safety fieldbus communication.
Auxiliary codes
Faults, warnings and events have 32-bit auxiliary codes, which help in finding the
problem.
See the tips in the Drive Composer PC tool for more information on the
auxiliary codes.
Reporting problems and failures
If you detect any failure in the safety module or safety functions, always contact your
local ABB representative.
Zero speed hit
Zero speed hit
(warning)
1)
System at safe
state
Speed values not in synchrony
Speeds not in
sync.
(warning)
1)
System at safe
state
Incident
Events depending on
the event type selection (parameter
Fault
Warning
Event
Problem in the
safety fieldbus
communication
(warning)
1)
System at safe
state
Limit/Incident
Events depending on
the event type selection (parameter
FSOGEN.62
)
Fault
Warning
Event
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...