354 Fault tracing
7A99
FSO passivated
FSO module was
passivated due to safety
fieldbus problems.
Check the fieldbus connection and
fieldbus controller for passivation
cause.
5)
Warnings
A7D0 FSO general
warnings
Warning from the FSO
module, for example:
• acknowledgement
button not operated
correctly
• I/O redundancy fault
See the tips in the Drive Composer
PC tool.
3)
A7D1 FSO internal fault
Internal fault in the FSO
module
Reboot the FSO module. If the
problem still exits, replace the FSO
module. Contact your local ABB
representative.
5) 3)
A7D2 FSO IO fault
Problems in the I/O
cabling or safety relays
Check the FSO I/O cabling.
4) 3)
A7D3 FSO STO fault
Problems in the STO
cabling or inside the drive
Check the FSO STO cabling.
4)
A7D4 FSO STO request FSO module received an
external STO request.
-
1)
A7D5 FSO
communication
fault
Fault in
FSO communication
Check all connections.
4) 3)
A7D6 FSO safety
fieldbus fault
Fault in FSO safety
fieldbus communication
Check all connections.
4) 3)
A7D7 FSO configuration
fault
Fault in FSO configuration Check the FSO module parameter
settings using Drive composer pro.
4)
A7D9 FSO encoderless
fault
Speed estimates differ too
much.
• Check the behavior of the driven
load compared with the drive
control parameter settings.
• Check that the drive is suitable for
the drive train and the motor.
• Adapt control parameters if gear
play or torsional rigidity causes
problems.
4)
A7DA FSO temperature
fault
FSO module temperature
is too high.
• Check ambient conditions. Reboot
the FSO module (switch the power
off and on or use drive parameter
96.09 FSO reboot
, see the drive
firmware manual).
• Make sure that cooling is sufficient.
Contact your local ABB
representative.
4)
Code
(hex)
Name
Cause
What to do
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...