![ABB FSO-12 Скачать руководство пользователя страница 166](http://html.mh-extra.com/html/abb/fso-12/fso-12_user-manual_2726166.webp)
166 PROFIsafe
Note
: When the FENA module is installed to the drive for the first time, you must set
the value of parameter
51/54.02
to one of the PROFINET profiles (value
11
if a drop-
down list is unavailable) and reboot the FENA module with parameter
51/54.27
. Only
after this, the rest of the parameters in group 51/54 get the correct texts and options.
If required, you must reconnect Drive composer pro to the drive to get the parameters
show up correctly (select
Refresh
from the
New
menu).
See the FENA user’s manual and the drive firmware manual for all necessary
parameter settings and detailed instructions on how to control the drive and motor
using the normal PROFINET cyclic communication.
Configuring the FSO module
Set the FSO module parameters as described in section
.
Configuring the safety PLC
After the drive has initialized the FENA adapter module, you must prepare the safety
PLC for communication with the adapter module. Examples of ABB AC500-S Safety
PLC and Siemens SIMATIC Fail-safe S7 PLC are given below. The examples include
the minimum required steps for starting the PROFINET and PROFIsafe
communication with the FENA and FSO modules. For detailed information, see the
documentation of your safety PLC.
Auto
Ethernet communication rate is negotiated
automatically by the device.
0
51/54.04…13 IP
CONFIGURATI
ON
The user can set the IP configuration for the
network in these parameters or in the PLC
project.
Static IP
0
51/54.20
Telegram type
Shows the telegram type for the selected I/O
communication.
This parameter is read-only.
PPO4
PPO Type 4
4
51/54.21
Alarm disable
Enables/disables the sending of diagnostic
messages to the PROFINET network.
Enabled
Diagnostic messages are sent.
0
51/54.27
FBA A/B PAR
REFRESH
Validates any changed FENA module
configuration settings and reboots the FENA
module taking all the changes to the drive
parameters in use. After refreshing, the value
reverts automatically to Done (0).
Note
: This parameter cannot be changed while
the drive is running.
REFRESH
Refreshing.
1
Index
Name/Value
Description
Example
value
Содержание FSO-12
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 12 safety functions module User s manual ...
Страница 4: ......
Страница 12: ...12 Table of contents ...
Страница 26: ...26 Introduction to the manual The PROFIsafe certificate for the FSO 12 module is attached below ...
Страница 36: ...36 Safety information and considerations ...
Страница 136: ...136 Safety functions ...
Страница 196: ...196 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 200: ...200 PROFIsafe ...
Страница 326: ...326 Start up ...
Страница 386: ...386 Dimension drawings ...