10 Operation
10.1
Operation of sensors
Fig. 18: Control elements
[1] Trimmers
[2] Trimmers
[3] Test LED
[4] Rocker button top
[5] Rocker button bottom
Notice
The function of the setting elements depends on the flex insert used.
Local operation via rocker button [4] / [5]
The attached sensor is designed as a rocker. Via this rocker function, the lighting can be
switched on and off independently of the movement detector function.
Rocker button top [4]:
– Brief press of the button:
– Switch on the light up to the expiration of the switch-off delay.
– Long press of the button:
– Mounting on relay insert or e-contact insert:
– Permanent light ON. The LED [3] lights up as status feedback signal.
– A renewed long press of the button exits the permanent mode.
– In permanent light ON mode, brief operation is not possible.
– Mounting on dimmer insert:
– Increase brightness up to the maximum brightness value.