Mounting
38 FEX300,
FEX500
OI/FEX300/FEX500-EN
The CCP potential must be diverted through a connecting line "A" away from the insulated
flowmeter sensor.
Fig. 30: Flowmeter sensor with grounding plate and functional ground
1
Insulated pipe
2
Functional ground
3
Grounding plate
A Connecting line for CCP potential
≥
4 mm
2
Cu, not included in the delivery,
to be provided onsite
B Insulated screw bolts without grounding
plates
4.7.9.2 Mixed system pipeline with CCP and functional ground potentials
This mixed system has an insulated pipeline with CCP potential and an uninsulated bar metal
pipe (L
=
1/4
x
flowmeter sensor size) with functional ground potential upstream and
downstream of the flowmeter sensor.
The Fig. 31 shows the preferred installation for cathodic corrosion protection systems.
Fig. 31: Flowmeter sensor with functional ground
1
Insulated pipe
2
Bare metal pipe
3
Functional ground
A Connecting line for CCP potential
≥
4 mm
2
Cu, not included in the delivery,
to be provided onsite
B Insulated screw bolts without grounding
plates