background image

OPTIONS FOR ABB DRIVES AND CONVERTERS

FEA-03 F-series extension adapter

User's manual

Содержание F Series

Страница 1: ... OPTIONS FOR ABB DRIVES AND CONVERTERS FEA 03 F series extension adapter User s manual ...

Страница 2: ......

Страница 3: ...A 03 F series extension adapter User s manual Table of contents 1 Safety instructions 4 Mechanical installation 5 Electrical installation 3AUA0000115811 Rev C EN Original instructions EFFECTIVE 2021 10 04 ...

Страница 4: ......

Страница 5: ...s 4 Mechanical installation 15 Contents of this chapter 15 Examining the delivery 15 Installing the extension adapter 16 Installing the adapter vertically on a DIN rail 17 Installing the adapter horizontally on a DIN rail 18 Installing an option module on the adapter 19 Removing an option module from the adapter 5 Electrical installation 21 Contents of this chapter 21 Connecting the adapter to the...

Страница 6: ...8 Technical data 27 Housing 27 Mounting 27 Power supply connection 27 Connectors 27 LED 27 Ambient conditions 28 Degree of protection 28 Standards 28 Dimensions Further information 6 Table of contents ...

Страница 7: ...use injury or death or damage to the equipment They also tell you how to prevent the danger Notes draw attention to a particular condition or fact or give information on a subject The manual uses these warning symbols WARNING Electricity warning tells about hazards from electricity which can cause injury or death or damage to the equipment WARNING General warning tells about conditions other than ...

Страница 8: ...ounding also reduces electromagnetic emission and interference Do not work on a powered drive After switching off the input power always allow the intermediate circuit capacitors 5 minutes to discharge before working on the drive the motor or the motor cable The motor cable terminals of the drive are at a dangerously high voltage when input power is applied regardless of motor operation There can ...

Страница 9: ...is intended for people who plan the installation install commission use and service the extension module Before you do work on the module read this manual and the applicable drive converter or inverter manual that contains the hardware and safety instructions for the product in question You are expected to know the fundamentals of electricity wiring electrical components and electrical schematic s...

Страница 10: ...ptional TTL absolute encoder interface module FEN 11 Optional resolver interface module FEN 21 Optional HTL incremental encoder interface module FEN 31 Optional digital I O extension module FIO 01 Optional analog I O extension module FIO 11 Hard Clad Silica A type of fiber optic cable HCS Plastic Optical Fibre A type of fiber optic cable POF Optical DDCS communication module RDCO Type of control u...

Страница 11: ...creases the number of F series option modules that can be connected to the control unit of the drive One or two option modules can be installed on one extension adapter The extension adapter is connected to the drive via a fiber optic link using the DDCS protocol Layout This figure shows the layout of the FEA 03 F series extension adapter The F series module connectors and front components such as...

Страница 12: ...tus LED for Slot 2 6 Node address switch C 7 Node address switch D 8 Power supply connector XPOW 9 Transmitter V1T and receiver V1R 10 Transmitter current selector 11 You can connect several FEA 03 extension adapters in a ring topology with a fibre optic cable See section Connecting the adapter to the drive control unit page 21 12 Hardware description ...

Страница 13: ...n These optical cable types can be used Plastic optical fibre POF cables max length 30 m 98 ft and Hard Clad Silica HCS cables max length 200 m 656 ft HCS cables allow longer connection distances because of their lower attenuation Note The optical components transmitter and receiver on a fibre optic link must be of the same type Hardware description 13 ...

Страница 14: ...14 ...

Страница 15: ... the extension adapter The housing of the extension adapter has two spring loaded latches for vertical or horizontal 35 x 7 5 mm DIN rail installation Install the DIN rail on a correctly grounded base If this is not possible use a separate grounding conductor Keep the grounding conductor as short as possible The cross sectional area must be at least 6 mm2 WARNING Install the adapter so that air ca...

Страница 16: ...l 1 Attach the support bracket in the correct position on the wall 2 Attach the latch to the back side of the adapter 3 Click the adapter to the DIN rail 4 Attach the adapter to the support bracket with two screws 1 3 2 4 16 Mechanical installation ...

Страница 17: ... Installing the adapter horizontally on a DIN rail 1 Attach the latches to the back side of the adapter 2 Click the adapter to the DIN rail 1 2 Mechanical installation 17 10 ...

Страница 18: ...option module into its position and push the module carefully into its position until the retaining clips lock it into position 4 Push in the lock 5 Fasten the screw Note The screw tightens the connections and grounds the module It is essential for fulfilling the EMC requirements and for correct operation of the module 2 4 3 1 5 18 Mechanical installation ...

Страница 19: ...Removing an option module from the adapter 1 Remove the screw 2 Pull out the lock and remove the module 2 1 Mechanical installation 19 10 ...

Страница 20: ...20 ...

Страница 21: ...ntrol unit through a DDCS communication module With the BCU control unit you can use an RDCO or FDCO communication module With the ZCU control unit you can use an FDCO communication module The FDCO reserves one option slot See the user s manual of the communication module for installation instructions This connection diagram shows how to connect the adapter to the communication module 5 Electrical...

Страница 22: ...0 m 20 25 m 2 MEDIUM 100 200 m 25 30 m 3 LONG 2 If you use an RDCO module set the channel parameter values in the drive control program Use RDCO channel 3 See the applicable drive firmware manual for more information 3 Set the FDCO or RDCO channel that is used to connect the FEA 03 module in the drive control program parameter 60 41 Extension adapter com port in ACS880 primary control program 4 Co...

Страница 23: ...rved Define the node IDs using the mechanical switches A and B Slot 1 and or C and D Slot 2 Switches A and C define the first digit and switches B and D the second digit of the node ID Setting the drive parameters Set the node IDs in the drive control program according to the option module type For example in ACS880 primary control program the parameters are I O extension modules parameters 14 02 ...

Страница 24: ...24 ...

Страница 25: ...are manual for fault and warning messages Diagnostic LEDs Description Color LED Is lit when power applied to the extension adapter is OK Green PWR OK Is lit when the initialization of the option module con nected to Slot 1 is OK Green SLOT 1 STATUS Is lit when the initialization of the option module con nected to Slot 2 is OK Green SLOT 2 STATUS 7 Diagnostics 25 ...

Страница 26: ...26 ...

Страница 27: ...er to I O extension module s User s manual Connectors Fiber optic link connection Avago Versatile Link 10 MBd Power supply connection Detachable screw terminal block Phoenix Contact MSTBA 2 5 2 G 5 08 LED See the diagnostics Ambient conditions The applicable ambient conditions specified for the drive in its hardware manual are in effect 8 Technical data 27 ...

Страница 28: ...Degree of protection IP20 Standards Complies with the safety standard IEC 61800 5 1 and EMC standard IEC 61800 3 Dimensions 28 Technical data ...

Страница 29: ... by navigating to www abb com searchchannels Product training For information on ABB product training navigate to new abb com service training Providing feedback on ABB manuals Your comments on our manuals are welcome Navigate to new abb com drives manuals feedback form Document library on the Internet You can find manuals and other product documents in PDF format on the Internet at www abb com dr...

Страница 30: ...www abb com drives 3AUA0000115811C Copyright 2021 ABB All rights reserved Specifications subject to change without notice 3AUA0000115811 Rev C EN EFFECTIVE 2021 10 04 ...