![ABB EXGP Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/abb/exgp/exgp_installation-manual_4403005.webp)
3
Mains Powered Pump
Unit (003000240)
NON HAZARDOUS AREA
HAZARDOUS AREA
(Zone 1, Class IIB)
Process
600
°
C to 1400
°
C
(1250
°
C
continuous)
EXGP Probe
Simple Device Conforming
to BS5345 Part 4: 1977
Mains Supply
R Type Thermocouple
mV Signal
(0 to 1400
°
C)
Two 4 to 20mA Output Signals
(0 to 1400
°
C and 0.25 to 25%O2)
or
4680 Transmitter
Mains Supply
Flameproof Interface Electronics Unit
EExd. IIB T6 Conforming to BS5501 Part 5: 1977
Flue
4685 Transmitter
Retransmission
Output
Reference Air Line Entry
Regulated Reference Air
Unit (003000241)
Mains Supply
O
2
mV Signal
(–20 to +180mV)
or
or
1
INTRODUCTION
Fig. 1.2 System Schematic