ABB EVLunic V1 Скачать руководство пользователя страница 5

E

N

Document: Rev. 1.00 / Document No.: 90333

  Date 21.08.2018

|

4

Anchoring to the base

The enclosed dowels must be used for anchoring (6 x Hilti HKD-ER compact dowels M8x30).

Technical data

M8

Anchorage ground

Standard concrete with a strength
class of C20/25-C50/60 or greater

Recommended load

Tension N (uncracked concrete)

4

Per dowel

Transversal shear V (uncracked con-
crete)

3,9 kN

Required clearance

10,5

cm

Torque Tinst

8 Nm

Drill-hole diameter do

10 mm

Drill-hole depth h1

33 mm

Specifications for compact dowels Hilti HKD-ER M8x30. Source: Hilti

Making drillholes

Mark the 6 holes on the concrete foundation using the baseplate of the floor-mounted
column.

Make sure that the connection cable is located precisely underneath the opening in the
baseplate.

Drill the 6 mounting holes:

Diameter: 10 mm
Drill-hole depth: 33 mm

Hammer the enclosed dowels using the Hilti HSD-G manual setting tool (not included
in the scope of delivery) so that they are flush with the floor.

Hilti HSD-G manual setting tool. Source: Hilti

Please also observe the following instructions:

Instructions on inserting the dowels. Source: Hilti

Содержание EVLunic V1

Страница 1: ...column Installation manual English Specifications are subject to change due to ongoing technical development Errors and omis sions excepted All rights reserved All intellectual property including trademarks and copyrights is the property of the respective owner Any unauthorized use of such intellectual property is expressly forbidden ...

Страница 2: ...onnel only2 This guide is a supplement to the Wallbox Installation Manual The information and instruc tions in the manual about selecting the location installation and connection of the charging station must be adhered to Intended use A floor mounted column for free standing installation in inside or outside areas is available as an alternative to mounting the charging station on a wall Depending ...

Страница 3: ... is designed for the installation of one charging station on the column V2 floor mounted column The V2 floor mounted column is designed for the installation of two charging stations on the column V3 floor mounted column The V3 floor mounted column is designed for the installation of two charging stations on the column ...

Страница 4: ...A horizontal level and sound foundation is required for installation To ensure safe and permanent anchoring we recommend creating a concrete founda tion 65cm L x 50cm W depth min frost limit but 40cm frost free Concrete C30 37 LP for XC4 XD1 XF4 or C25 30 LP for XC4 XD1 XF2 reinforced concrete BSt 500 S BSt 500 M The base must permit the running off of any water that has entered the base All cable...

Страница 5: ...rill hole depth h1 33 mm Specifications for compact dowels Hilti HKD ER M8x30 Source Hilti Making drillholes Mark the 6 holes on the concrete foundation using the baseplate of the floor mounted column Make sure that the connection cable is located precisely underneath the opening in the baseplate Drill the 6 mounting holes Diameter 10 mm Drill hole depth 33 mm Hammer the enclosed dowels using the ...

Страница 6: ...read in cable Thread the connection cables from the bottom through the column upwards through the cable opening Anchoring Anchoring Position the column directly over the cable outlet Anchor the column to the foundation using the 6 hexagon bolts Grounding point Grounding If necessary connect the earthing to the column s grounding point ...

Страница 7: ... column example Mounting the charging stations Mount the charging stations on the column using the enclosed screws Connecting and commissioning Perform the electrical connection and commissioning in accordance with the instructions in the Installation manual Holder for charging cable Mount the holder for the charging cable option Mount the holder for the charging cable on the floor mounted column ...

Страница 8: ...Document V 1 00 Document No 90333 Date 21 08 2018 7 ...

Отзывы: